Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/73914
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Medina, Alfonso | en_US |
dc.contributor.author | Hernández, Enrique | en_US |
dc.contributor.author | Suárez de Lezo, José María | en_US |
dc.contributor.author | Pan, Manuel | en_US |
dc.contributor.author | Melián, Francisco | en_US |
dc.contributor.author | Romero Moreno, Miguel Ángel | en_US |
dc.contributor.author | Marrero, J. | en_US |
dc.contributor.author | Irurita, M. | en_US |
dc.contributor.author | Pavlovic, Djordje | en_US |
dc.date.accessioned | 2020-08-02T16:38:38Z | - |
dc.date.available | 2020-08-02T16:38:38Z | - |
dc.date.issued | 1992 | en_US |
dc.identifier.issn | 1042-3931 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/73914 | - |
dc.description.abstract | This article shows the findings observed in a group of 7 patients with short coronary lesions who were treated by a divided (7 mm length) coronary Palmaz-Schatz(TM) stent, in trying to match the length of the stent to that of the treated segment. All of the patients were male and had a mean age of 59 +/- 5 years; 6 had unstable and 1 stable angina. The angiographic length of the lesion was 4.3 +/- 1 mm. The divided stent was successfully deployed in all cases and remained in place without complications. The clinical condition stabilized and all 7 patients were symptom-free 6 months post-hospital discharge. At angiographic follow-up studies, performed before discharge and at 2 and 6 months later, there were no significant changes in the resultant minimal lumen diameter. The stented segment and surrounding areas remained smooth and without intraluminal defects. These observations suggest that a 7 mm length stent is effective in avoiding elastic recoil of discrete coronary lesions. This reduced length could be helpful in: 1) decreasing exposed metallic surface, 2) increasing deliverability and 3) preventing the origin of nearby side-branches to be covered by a standard 15 mm length stent. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Invasive Cardiology | en_US |
dc.source | Journal of Invasive Cardiology [ISSN 1042-3931], v. 4 (8), p. 389-392, (Octubre 1992) | en_US |
dc.subject | 320501 Cardiología | en_US |
dc.subject.other | Stents | en_US |
dc.subject.other | Palmaz-Schatz Stent | en_US |
dc.title | Divided Palmaz-Schatz(Tm) stent for discrete coronary stenosis | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.pmid | 10147841 | - |
dc.identifier.scopus | 0026928825 | - |
dc.identifier.isi | A1992JV64900004 | - |
dc.contributor.authorscopusid | 7202723590 | - |
dc.contributor.authorscopusid | 7402296666 | - |
dc.contributor.authorscopusid | 7006785516 | - |
dc.contributor.authorscopusid | 7202544866 | - |
dc.contributor.authorscopusid | 7003549899 | - |
dc.contributor.authorscopusid | 7202430759 | - |
dc.contributor.authorscopusid | 7005957537 | - |
dc.contributor.authorscopusid | 6508272985 | - |
dc.contributor.authorscopusid | 7005198171 | - |
dc.description.lastpage | 392 | en_US |
dc.identifier.issue | 8 | - |
dc.description.firstpage | 389 | en_US |
dc.relation.volume | 4 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 5831803 | - |
dc.contributor.daisngid | 2740671 | - |
dc.contributor.daisngid | 476437 | - |
dc.contributor.daisngid | 77557 | - |
dc.contributor.daisngid | 4882689 | - |
dc.contributor.daisngid | 156230 | - |
dc.contributor.daisngid | 33557 | - |
dc.contributor.daisngid | 1534651 | - |
dc.contributor.daisngid | 831427 | - |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:MEDINA, A | - |
dc.contributor.wosstandard | WOS:HERNANDEZ, E | - |
dc.contributor.wosstandard | WOS:DELEZO, JS | - |
dc.contributor.wosstandard | WOS:PAN, M | - |
dc.contributor.wosstandard | WOS:MELIAN, F | - |
dc.contributor.wosstandard | WOS:ROMERO, M | - |
dc.contributor.wosstandard | WOS:MARRERO, J | - |
dc.contributor.wosstandard | WOS:IRURITA, M | - |
dc.contributor.wosstandard | WOS:PAVLOVIC, D | - |
dc.date.coverdate | Octubre 1992 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
Colección: | Artículos |
Citas SCOPUSTM
5
actualizado el 30-mar-2025
Citas de WEB OF SCIENCETM
Citations
3
actualizado el 25-feb-2024
Visitas
99
actualizado el 21-sep-2024
Google ScholarTM
Verifica
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.