Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/71352
Título: Trasplante pulmonar en ratas. Un modelo viable de estudio experimental
Otros títulos: Lung Transplantation in Rats: a Viable Experimental Model
Autores/as: Ponce González, José María
Santana, N.
López García, A.
Freixenet, J.
Martín Barrasa, J.L.
Rodríguez Suárez, Pedro Miguel 
Clasificación UNESCO: 3205 Medicina interna
321314 Cirugía de los trasplantes
Palabras clave: Trasplante pulmonar
Cirugía experimental
Trasplante experimental
Lung transplant
Experimental surgery, et al.
Fecha de publicación: 2004
Publicación seriada: Archivos de Bronconeumologia 
Resumen: Objetivos: Desarrollar el modelo experimental de trasplante pulmonar (TP) con cuffs (técnica de manguito), inicialmente descrito por Mizuta, como medio de estudio del TP en nuestro medio incorporando un nuevo protocolo anestésico rápido, seguro y reversible. Material y método: Se han utilizado ratas Sprague-Dawley (n = 88) para el desarrollo del modelo experimental y se han logrado realizar 30 TP izquierdos (n = 60). En el animal donante se han efectuado una esternotomía media y extracción del bloque cardiopulmonar con disección del pulmón izquierdo y colocación de los cuffs (catéteres de venopunción cortados en cilindros de 3 mm). En el receptor, a través de una toracotomía lateral, se ha llevado a cabo el implante del pulmón izquierdo mediante las anastomosis con cuffs. Se han valorado el tiempo quirúrgico y las complicaciones postoperatorias, así como la presencia de signos de lesión de isquemia-reperfusión y rechazo agudo en el pulmón trasplantado. Resultados: Durante el desarrollo del modelo experimental rechazamos a 8 animales en la extracción. Tras completarla satisfactoriamente, no se pudo realizar el implante en 10 ratas por problemas técnicos. De los animales trasplantados, 4 fallecieron en las primeras 24 h y 26 ratas sobrevivieron hasta las 48 h, momento en que fueron sacrificadas. Hallamos un buen estado de las anastomosis y signos de lesión de isquemia-reperfusión y rechazo agudo en el parénquima pulmonar del pulmón trasplantado. Conclusiones: El TP con cuffs en ratas es un modelo válido, fiable, reproducible y económico para el estudio del TP y de los fenómenos de isquemia-reperfusión y rechazo. La técnica quirúrgica es compleja, tiene una larga curva de aprendizaje y requiere personal con experiencia quirúrgica. Además, es subsidiaria de modificaciones que hagan que se asemeje más a la técnica quirúrgica utilizada en clínica humana para interpretar mejor y poder extrapolar los resultados al humano con más fiabilidad.
Objectives: To incorporate a new fast, safe, and reversible anesthetic procedure into the experimental model of lung transplantation (LT) using a cuff technique originally described by Mizuta. Material And Method: Eighty-eight Sprague-Dawley rats were used in the experimental model. Thirty left LTs were performed, using 60 rats. The donor heart-lung block was excised by median sternotomy with dissection of the left lung and cuffs (intravenous catheters cut into 3-mm sections) were put in place. The left lung was implanted in the recipient by lateral thoracotomy using the cuffs for anastomoses. The duration of surgery and postoperative complications were recorded. Also noted were signs of ischemia-reperfusion injury, and acute rejection of the transplanted lung. Results: We discarded lungs excised from 8 animals when developing the experimental model. Transplants could not be completed in 10 rats due to technical problems, despite satisfactory excision. Of the rats who received a transplant, 4 died in the first 24 hours and 26 survived to 48 hours. They were then killed and examined. The state of the anastomoses was good and signs of ischemia-reperfusion injury, as well as acute rejection were observed in the parenchyma of the transplanted lung. Conclusions: LT with cuffs in rats is a valid, reliable, reproducible, and cheap model for studying ischemia-reperfusion injury and rejection in LT. The surgical technique is complex, requiring experienced surgeons and a long learning process. Modification of the technique to more closely resemble the surgical procedure in humans is possible, thus facilitating interpretation and allowing more reliable extrapolation to humans.
URI: http://hdl.handle.net/10553/71352
ISSN: 0300-2896
DOI: 10.1016/S0300-2896(04)75568-4
Fuente: Archivos de bronconeumología: Órgano oficial de la Sociedad Española de Neumología y Cirugía Torácica SEPAR y la Asociación Latinoamericana de Tórax ( ALAT ) [ISSN 0300-2896], v. 40 (10), p. 438-442