Please use this identifier to cite or link to this item:
https://accedacris.ulpgc.es/handle/10553/71087
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Villa, Enrique | en_US |
dc.contributor.author | Arteaga-Marrero, Natalia | en_US |
dc.contributor.author | Ruiz Alzola, Juan Bautista | en_US |
dc.date.accessioned | 2020-03-27T09:16:09Z | - |
dc.date.available | 2020-03-27T09:16:09Z | - |
dc.date.issued | 2020 | en_US |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/71087 | - |
dc.description.abstract | Thermal imaging is a promising technology in the medical field. Recent developments in low-cost infrared (IR) sensors, compatible with smartphones, provide competitive advantages for home-monitoring applications. However, these sensors present reduced capabilities compared to more expensive high-end devices. In this work, the characterization of thermal cameras is described and carried out. This characterization includes non-uniformity (NU) effects and correction as well as the thermal cameras’ dependence on room temperature, noise-equivalent temperature difference (NETD), and response curve stability with temperature. Results show that low-cost thermal cameras offer good performance, especially when used in temperature-controlled environments, providing evidence of the suitability of such sensors for medical applications, particularly in the assessment of diabetic foot ulcers on which we focused this study. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Sensors | en_US |
dc.source | Sensors [ISSN 1424-8220], v. 20 (5), 1321 | en_US |
dc.subject | 530602 Innovación tecnológica | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject.other | Thermal cameras | en_US |
dc.subject.other | Low-cost | en_US |
dc.subject.other | Medical applications | en_US |
dc.subject.other | Diabetic foot | en_US |
dc.subject.other | Microbolometer | en_US |
dc.subject.other | NETD | en_US |
dc.subject.other | Non-uniformity | en_US |
dc.title | Performance assessment of low-cost thermal cameras for medical applications | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/s20051321 | en_US |
dc.identifier.pmid | 20 | - |
dc.identifier.scopus | 2-s2.0-85080938054 | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.identifier.issue | 5 | - |
dc.description.firstpage | 1321 | en_US |
dc.relation.volume | 20 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.notas | This article belongs to the Special Issue Biomedical Infrared Imaging: From Sensors to Applications Ⅱ | en_US |
dc.utils.revision | Sí | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,636 | |
dc.description.jcr | 3,576 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
41
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
34
checked on Mar 30, 2025
Page view(s)
107
checked on Aug 10, 2024
Download(s)
119
checked on Aug 10, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.