Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/70137
Title: Preclinical Strength Checking for Artificial Pelvic Prosthesis under Multi-activities - A Case Study
Authors: Dong, Enchun
Iqbal, Taimoor
Fu, Jun
Li, Dichen
Liu, Bin
Guo, Zheng
Cuadrado Hernández, Alberto Javier 
Zhen, Zhen
Wang, Ling
Fan, Hongbin
UNESCO Clasification: 331402 Prótesis
Keywords: Bionic Prosthesis
Finite Element Analysis
Multi-Activities
Pelvis
Issue Date: 2019
Journal: Journal of Bionic Engineering 
Abstract: Customized prostheses are normally employed to reconstruct the biomechanics of the pelvis after resection due to tumors or accidents. The objective of this study is to evaluate the biomechanics of the pelvis under different daily activities and to establish a functional evaluation methodology for the customized prostheses. For this purposes, finite element model of a healthy pelvis as well as a reconstructed pelvic model after type II+III resection were built for biomechanical study. The biomechanical performance of the healthy and reconstructed pelvic model was studied under routine activities including standing, knee bending, sitting down, standing up, walking, stair descent and stair ascent. Subsequently, the strength and stability of the prosthesis were evaluated under these activities. Results showed that, for the heathy pelvic model, the stresses were mainly concentrated around the upper part of the sacrum and the sacroiliac joint undergoing different activities, and the maximum stress occurred during stair ascent. As for the reconstructed pelvis, the stress distribution and the tendency of the maximum stress variation predicted for the bone part during all the activities were similar to those of the natural pelvic model, which indicated that the load transferring function of the reconstructed pelvis could be restored by the prosthesis. Moreover, the predicted maximum von Mises stress of the screws and prosthesis was below the fatigue strength of the 3D printed Ti-6Al-4V, which indicated the prosthesis can provide a reliable mechanical performance after implantation.
URI: http://hdl.handle.net/10553/70137
ISSN: 1672-6529
DOI: 10.1007/s42235-019-0121-5
Source: Journal of Bionic Engineering [ISSN 1672-6529], v. 16 (6), p. 1092-1102
Appears in Collections:Artículos
Show full item record

SCOPUSTM   
Citations

10
checked on Nov 17, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 17, 2024

Page view(s)

65
checked on May 4, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.