Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/69952
DC FieldValueLanguage
dc.contributor.authorRamos De Miguel, Ángelen_US
dc.contributor.authorDurmo, Irfanen_US
dc.contributor.authorFalcón González, Juan Carlosen_US
dc.contributor.authorBorkoski Barreiro, Silviaen_US
dc.contributor.authorRamos Macías, Angelen_US
dc.date.accessioned2020-02-05T12:51:32Z-
dc.date.accessioned2020-07-06T10:37:05Z-
dc.date.available2020-02-05T12:51:32Z-
dc.date.available2020-07-06T10:37:05Z-
dc.date.issued2019en_US
dc.identifier.issn1531-7129en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/69952-
dc.description.abstractINTRODUCTION: The radiological analysis following a cochlear implantation offers insight into the audiological outcomes of cochlear implant recipients. The wrapping factor (WF) is the most common radiological analysis measuring the modiolar position and depth of insertion of an electrode array. New measurements like the intracochlear position index (ICPI) or the homogeneity factor (HF) can offer more accurate information regarding the electrode's intracochlear position. We have also studied a new method to calculate the WF, by normalizing it with a new methodology (WFn). OBJECTIVES: To analyze and compare the results of the WF, ICPI, HF, and WFn obtained using a cone beam computer tomography (CBCT) with the histological analysis on temporal bone. MATERIAL: A perimodiolar electrode array (Nucleus Slim CI532) was inserted in three temporal bones. A perfect insertion was performed in the first temporal bone, according to the correct specifications. In the second specimen, a slightly over-inserted electrode was analyzed and in the third specimen a completely over-inserted electrode array was studied. METHOD: A CBCT was performed following the implantations and then, a histological analysis with slices perpendicular to the cochlea axis (modiolus). Each measurement was made 10 times by 10 experts (radiologist and otologist) with a total amount of 600 measurements (100 for each data, 3 CBCT and 3 histology). A t test statistical analysis was performed to compare the measurements between CBCT and histology. RESULTS: It was observed that the ICPI and the HF correctly identify the three different insertions. Regarding the WF no significant difference in the two over-inserted specimens was found. The ICPI was the only measurement that shows no statistical difference between the CBCT and the histology, so it was considered the most accurate method. Finally, the WF shows a statistical difference between the CBCT and the histology in all cases, indicating the poor value of the radiological method. The WFn analysis includes the modiolar wall length in the measurement. This improves the final result as it reduces the error induced by the size of the cochlea. CONCLUSION: The ICPI and the HF provide better radiological information than the WF, regarding the intracochlear position of the electrode array. The most relevant difference is that the ICPI, HF, and WFn include modiolar and lateral wall dimensions, thereby using the diameter of the cochlear duct for the analysis.en_US
dc.languageengen_US
dc.relation.ispartofOtology and Neurotologyen_US
dc.sourceOtology & neurotology [ISSN 1531-7129], v. 50(5S), p. S10-S17en_US
dc.subject320507 Neurologíaen_US
dc.subject.otherBeam Computed-Tomographyen_US
dc.subject.otherPostoperative Assessmenten_US
dc.subject.otherCochlear Implantsen_US
dc.subject.otherInsertionen_US
dc.subject.otherDepthen_US
dc.subject.otherToolen_US
dc.subject.otherCten_US
dc.titleEvaluation of Intracochlear Position of a Slim Modiolar Electrode Array, by Using Different Radiological Analysesen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.relation.conferenceMeeting of the International-Society-for-Otologic-Surgery-and-Science
dc.identifier.doi10.1097/MAO.0000000000002213en_US
dc.identifier.scopus85068493435-
dc.identifier.isi000509676500003-
dc.contributor.authorscopusid56848284600-
dc.contributor.authorscopusid55630543700-
dc.contributor.authorscopusid36618690700-
dc.contributor.authorscopusid55371597700-
dc.contributor.authorscopusid6701550535-
dc.description.lastpageS17en_US
dc.identifier.issue5S Suppl 1-
dc.description.firstpageS10en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid2433059-
dc.contributor.daisngid11459466-
dc.contributor.daisngid31467205-
dc.contributor.daisngid7419147-
dc.contributor.daisngid2160095-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:de Miguel, AR-
dc.contributor.wosstandardWOS:Durmo, I-
dc.contributor.wosstandardWOS:Gonzalez, JCF-
dc.contributor.wosstandardWOS:Barreiro, SB-
dc.contributor.wosstandardWOS:Macias, AR-
dc.date.coverdateJunio 2019en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr1,169
dc.description.jcr1,712
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR SIANI: Modelización y Simulación Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Informática y Sistemas-
crisitem.author.deptGIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptGIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptGIR SIANI: Ingeniería biomédica aplicada a estimulación neural y sensorial-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-0528-815X-
crisitem.author.orcid0000-0002-5743-4374-
crisitem.author.orcid0000-0002-4709-5559-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.fullNameRamos De Miguel, Ángel-
crisitem.author.fullNameFalcon Gonzalez,Juan Carlos-
crisitem.author.fullNameBorkoski Barreiro,Silvia-
crisitem.author.fullNameRamos Macías, Ángel Manuel-
Appears in Collections:Artículos
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.