Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/69949
Title: | Diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM): a retrospective study involving 644 breast lesions | Authors: | Travieso-Aja, María del Mar Maldonado-Saluzzi, Daniel Naranjo-Santana, Pedro Fernández-Ruiz, Claudia Severino-Rondón, Wilsa Rodríguez Rodríguez, Mario Vega Benítez, Víctor Manuel Pérez-Luzardo, Octavio |
UNESCO Clasification: | 32 Ciencias médicas | Keywords: | Breast Cancer Breast Ultrasound Contrast-Enhanced Dual-Energy Spectral Mammography (Cesm) Digital Mammography Iodinated Contrast Medium |
Issue Date: | 2019 | Journal: | Radiologia Medica | Abstract: | Objective: To evaluate the diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM) in comparison with that of full-field digital mammography (FFDM), either alone or accompanied with breast ultrasound (BUS) in a large series of patients/breast lesions (n = 644). Patients and methods: In this retrospective study, five radiologists evaluated the lesions by three imaging modalities: FFDM, FFDM + BUS, and CESM and compared the imaging to the gold standard (histopathology or clinical follow-up). Diagnostic performance parameters and receiver operating characteristic (ROC) curves of CESM were calculated and compared to those of FFDM or FFDM + BUS (McNemar’s test). Additionally, the reliability of tumor size measurement by CESM was compared with the histopathological measurement. Results: The study included 218 benign and 426 malignant lesions. 85% of benign and 93% of malignant lesions were adequately identified using CESM. With respect to FFDM and FFDM + BUS, CESM significantly increased sensitivity to 93.2% (+ 10.7% and + 3.4%, respectively); specificity to 84.4% (+ 15.8% and + 1.7%, respectively); PPV to 92.3% (+ 26.8% and + 3.6%, respectively); NPV to 86.0% (+ 1.6% and + 1.8%, respectively); and accuracy to 90.2% (+ 15.8% and + 3.2%, respectively). In the ROC curves analyses, the comparison among the three AUC values was also statistically significant (p < 0.001). Good agreement between tumor diameters measured using CESM and histopathology was observed (Spearman’s rank correlation, r = 0.891, p < 0.0001), although this technique tended to produce an overestimation of the size (+ 7 mm). Conclusions: CESM has high diagnostic accuracy and can be considered as a useful technique for the assessment of breast lesions. | URI: | http://hdl.handle.net/10553/69949 | ISSN: | 0033-8362 | DOI: | 10.1007/s11547-019-01056-2 | Source: | Radiologia Medica [ISSN 0033-8362], v. 124 (10), p. 1006-1017 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
23
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
21
checked on Nov 17, 2024
Page view(s)
63
checked on Jul 29, 2023
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.