Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/69935
Título: Staged Instrumentation With Magnetically Controlled Growing Rods in Early-Onset Scoliosis: Indications and Preliminary Outcomes
Autores/as: Peiro-Garcia, Alejandro
Bourget-Murray, Jonathan
Suárez Lorenzo, Isadora
Parsons, David
Ferri-de-Barros, Fabio
Clasificación UNESCO: 321315 Traumatología
Palabras clave: Eos
Growing Rods
MCGR
Pediatric Spine
Scoliosis
Fecha de publicación: 2019
Publicación seriada: Spine Deformity 
Resumen: Severe scoliosis, kyphosis, stiffer curves, short trunk height, and poor bone density are known risk factors for instrumentation failure with traditional growing rods or magnetically controlled growing rods (MCGR). To minimize the risk of instrumentation failure in managing classification early-onset scoliosis (EOS) with MCGR, we propose a strategy for staged MCGR insertion. Methods: We performed a single-center retrospective review of all consecutive MCGR cases with 24 months’ minimum follow-up. Inclusion criteria included diagnosis of EOS of any etiology with severe and stiff curves in the coronal or sagittal planes, poor bone density, short trunk height (T1–T12 smaller than 150 mm) or previous instrumentation failure managed with staged MCGR. During the first stage, anchor points and halo-gravity were applied, followed by halo-gravity traction. At a second stage, halo-gravity was removed and MCGR were inserted. Outcome measures included pre- and postoperative radiographic measurements and complications. Results: Seventeen patients with a median age of seven (range: six to nine) years were managed in two stages. Indications for two-stage surgery were short trunk height (T1–T12 height less than 150 mm) in six patients, five poor bone quality, three dislodgement of proximal anchor points in previous instrumentation, and three rigid curves. The rate of unplanned revision surgeries was 11.8%. No infections or traction-related complications were found. Conclusions: According to our results, the staged MCGR insertion strategy combined with halo-gravity traction to manage complex EOS yielded a relatively low instrumentation failure rate as compared with the rates previously reported in the current literature. To our knowledge, this is the first study reporting the staged strategy for instrumentation with MCGR. Level of Evidence: Level IV.
URI: http://hdl.handle.net/10553/69935
ISSN: 2212-134X
DOI: 10.1007/s43390-020-00045-0
Fuente: Spine Deformity [ISSN 2212-134X], v. 8, 317-325
Colección:Artículos
Vista completa

Citas SCOPUSTM   

2
actualizado el 14-abr-2024

Visitas

188
actualizado el 14-oct-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.