Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/55391
Title: | Reproducibility andrRepeatability of five different technologies for Bar velocity measurement in resistance training | Authors: | Courel-Ibáñez, Javier Martínez-Cava, Alejandro Morán-Navarro, Ricardo Escribano-Peñas, Pablo Chavarren-Cabrero, Javier González-Badillo, Juan José Pallarés, Jesús G |
UNESCO Clasification: | 241106 Fisiología del ejercicio | Keywords: | Exercise testing Monitoring Standard error of measurement Strength performance Validity, et al |
Issue Date: | 2019 | Journal: | Annals of Biomedical Engineering | Abstract: | This study aimed to analyze the agreement between five bar velocity monitoring devices, currently used in resistance training, to determine the most reliable device based on reproducibility (between-device agreement for a given trial) and repeatability (between-trial variation for each device). Seventeen resistance-trained men performed duplicate trials against seven increasing loads (20-30-40-50-60-70-80 kg) while obtaining mean, mean propulsive and peak velocity outcomes in the bench press, full squat and prone bench pull exercises. Measurements were simultaneously registered by two linear velocity transducers (LVT), two linear position transducers (LPT), two optoelectronic camera-based systems (OEC), two smartphone video-based systems (VBS) and one accelerometer (ACC). A comprehensive set of statistics for assessing reliability was used. Magnitude of errors was reported both in absolute (m s-1) and relative terms (%1RM), and included the smallest detectable change (SDC) and maximum errors (MaxError). LVT was the most reliable and sensitive device (SDC 0.02-0.06 m s-1, MaxError 3.4-7.1% 1RM) and the preferred reference to compare with other technologies. OEC and LPT were the second-best alternatives (SDC 0.06-0.11 m s-1), always considering the particular margins of error for each exercise and velocity outcome. ACC and VBS are not recommended given their substantial errors and uncertainty of the measurements (SDC > 0.13 m s-1). | URI: | http://hdl.handle.net/10553/55391 | ISSN: | 0090-6964 | DOI: | 10.1007/s10439-019-02265-6 | Source: | Annals of Biomedical Engineering [ISSN 0090-6964], p. 1-16 | URL: | https://api.elsevier.com/content/abstract/scopus_id/85064450478 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
129
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
121
checked on Mar 30, 2025
Page view(s)
45
checked on Sep 9, 2023
Download(s)
476
checked on Sep 9, 2023
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.