Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/52253
Campo DC Valoridioma
dc.contributor.authorMauriz, E.
dc.contributor.authorCalle, A.
dc.contributor.authorManclús, J. J.
dc.contributor.authorMontoya, A.
dc.contributor.authorEscuela, A. M.
dc.contributor.authorSendra, J. R.
dc.contributor.authorLechuga, L. M.
dc.date.accessioned2018-11-25T18:44:17Z-
dc.date.available2018-11-25T18:44:17Z-
dc.date.issued2006
dc.identifier.issn0925-4005
dc.identifier.urihttp://hdl.handle.net/10553/52253-
dc.description.abstractOn-line determination of pollutants within the two main types of cholinesterase inhibitors: organophosphate pesticide chlorpyrifos and carbaryl, a carbamate insecticide, is carried out by a new developed surface plasmon resonance (SPR) optical immunosensor. Two different immunoassay approaches have been tested to detect the target analytes by using individual and simultaneous immobilization formats. The formation of an alkanethiol self-assembled monolayer (SAM) allows the repeated use of the same sensor surface. The regeneration of the immunosurface is accomplished throughout approximately 200 assay cycles without degradation of the covalently immobilized molecule. Sensor surface reusability is also evaluated by assessing the SPR signal deviation from the initial value at the beginning of the analysis. Detection limits reached ppt levels (52 and 58 ng L-1) when using chlorpyrifos both individual and multi-analyte protocols. For carbaryl single and simultaneous immunoassay formats, limits of detection were obtained within the 1.41-0.47 mu g L-1 range. The immunosensor response comprised 20 min for a complete assay cycle. The SPR-sensor system developed is already commercialised by the company SENSIA, S.L. (c) 2006 Elsevier B.V. All rights reserved.
dc.publisher0925-4005
dc.relation.ispartofSensors and Actuators, B: Chemical
dc.sourceSensors and Actuators, B: Chemical[ISSN 0925-4005],v. 118, p. 399-407
dc.subject.otherCarbamate Pesticides
dc.subject.otherAntibody-Production
dc.subject.otherWater Samples
dc.subject.otherChlorpyrifos
dc.subject.otherBiosensors
dc.subject.otherCarbaryl
dc.subject.otherImmunosensor
dc.subject.otherOrganophosphate
dc.subject.otherDrinking
dc.subject.otherFormats
dc.titleSingle and multi-analyte surface plasmon resonance assays for simultaneous detection of cholinesterase inhibiting pesticides
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.relation.conference19th European Conference on Solid-State Transducers
dc.identifier.doi10.1016/j.snb.2006.04.085
dc.identifier.scopus33747866655
dc.identifier.isi000241165800064
dc.contributor.authorscopusid12142115700
dc.contributor.authorscopusid7004543420
dc.contributor.authorscopusid6603537415
dc.contributor.authorscopusid7005990597
dc.contributor.authorscopusid7801316877
dc.contributor.authorscopusid57192419185
dc.contributor.authorscopusid7006497287
dc.contributor.authorscopusid6603774181
dc.description.lastpage407
dc.description.firstpage399
dc.relation.volume118
dc.type2Artículoes
dc.contributor.daisngid2382052
dc.contributor.daisngid32184756
dc.contributor.daisngid1064561
dc.contributor.daisngid664603
dc.contributor.daisngid5534772
dc.contributor.daisngid34948786
dc.contributor.daisngid214602
dc.contributor.wosstandardWOS:Mauriz, E
dc.contributor.wosstandardWOS:Calle, A
dc.contributor.wosstandardWOS:Manclus, JJ
dc.contributor.wosstandardWOS:Montoya, A
dc.contributor.wosstandardWOS:Escuela, AM
dc.contributor.wosstandardWOS:Sendra, JR
dc.contributor.wosstandardWOS:Lechuga, LM
dc.date.coverdateOctubre 2006
dc.identifier.conferenceidevents120524
dc.identifier.ulpgces
dc.description.jcr2,331
dc.description.jcrqQ1
dc.description.scieSCIE
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUIBS: Medicina Veterinaria e Investigación Terapéutica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos-
crisitem.author.deptGIR IUMA: Equipos y Sistemas de Comunicación-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.deptGIR IUMA: Equipos y Sistemas de Comunicación-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.orcid0000-0002-2683-7592-
crisitem.author.orcid0000-0002-9634-7871-
crisitem.author.orcid0000-0001-5385-792X-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.fullNameMontoya Alonso, José Alberto-
crisitem.author.fullNameMedina Escuela, Alfonso Francisco-
crisitem.author.fullNameSendra Sendra,José Ramón-
crisitem.event.eventsstartdate11-09-2005-
crisitem.event.eventsenddate14-09-2005-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.