dc.contributor.author | Mauriz, E. | |
dc.contributor.author | Calle, A. | |
dc.contributor.author | Manclús, J. J. | |
dc.contributor.author | Montoya, A. | |
dc.contributor.author | Escuela, A. M. | |
dc.contributor.author | Sendra, J. R. | |
dc.contributor.author | Lechuga, L. M. | |
dc.date.accessioned | 2018-11-25T18:44:17Z | - |
dc.date.available | 2018-11-25T18:44:17Z | - |
dc.date.issued | 2006 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.uri | http://hdl.handle.net/10553/52253 | - |
dc.description.abstract | On-line determination of pollutants within the two main types of cholinesterase inhibitors: organophosphate pesticide chlorpyrifos and carbaryl, a carbamate insecticide, is carried out by a new developed surface plasmon resonance (SPR) optical immunosensor. Two different immunoassay approaches have been tested to detect the target analytes by using individual and simultaneous immobilization formats. The formation of an alkanethiol self-assembled monolayer (SAM) allows the repeated use of the same sensor surface. The regeneration of the immunosurface is accomplished throughout approximately 200 assay cycles without degradation of the covalently immobilized molecule. Sensor surface reusability is also evaluated by assessing the SPR signal deviation from the initial value at the beginning of the analysis. Detection limits reached ppt levels (52 and 58 ng L-1) when using chlorpyrifos both individual and multi-analyte protocols. For carbaryl single and simultaneous immunoassay formats, limits of detection were obtained within the 1.41-0.47 mu g L-1 range. The immunosensor response comprised 20 min for a complete assay cycle. The SPR-sensor system developed is already commercialised by the company SENSIA, S.L. (c) 2006 Elsevier B.V. All rights reserved. | |
dc.publisher | 0925-4005 | |
dc.relation.ispartof | Sensors and Actuators, B: Chemical | |
dc.source | Sensors and Actuators, B: Chemical[ISSN 0925-4005],v. 118, p. 399-407 | |
dc.subject.other | Carbamate Pesticides | |
dc.subject.other | Antibody-Production | |
dc.subject.other | Water Samples | |
dc.subject.other | Chlorpyrifos | |
dc.subject.other | Biosensors | |
dc.subject.other | Carbaryl | |
dc.subject.other | Immunosensor | |
dc.subject.other | Organophosphate | |
dc.subject.other | Drinking | |
dc.subject.other | Formats | |
dc.title | Single and multi-analyte surface plasmon resonance assays for simultaneous detection of cholinesterase inhibiting pesticides | |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.relation.conference | 19th European Conference on Solid-State Transducers | |
dc.identifier.doi | 10.1016/j.snb.2006.04.085 | |
dc.identifier.scopus | 33747866655 | |
dc.identifier.isi | 000241165800064 | |
dc.contributor.authorscopusid | 12142115700 | |
dc.contributor.authorscopusid | 7004543420 | |
dc.contributor.authorscopusid | 6603537415 | |
dc.contributor.authorscopusid | 7005990597 | |
dc.contributor.authorscopusid | 7801316877 | |
dc.contributor.authorscopusid | 57192419185 | |
dc.contributor.authorscopusid | 7006497287 | |
dc.contributor.authorscopusid | 6603774181 | |
dc.description.lastpage | 407 | |
dc.description.firstpage | 399 | |
dc.relation.volume | 118 | |
dc.type2 | Artículo | es |
dc.contributor.daisngid | 2382052 | |
dc.contributor.daisngid | 32184756 | |
dc.contributor.daisngid | 1064561 | |
dc.contributor.daisngid | 664603 | |
dc.contributor.daisngid | 5534772 | |
dc.contributor.daisngid | 34948786 | |
dc.contributor.daisngid | 214602 | |
dc.contributor.wosstandard | WOS:Mauriz, E | |
dc.contributor.wosstandard | WOS:Calle, A | |
dc.contributor.wosstandard | WOS:Manclus, JJ | |
dc.contributor.wosstandard | WOS:Montoya, A | |
dc.contributor.wosstandard | WOS:Escuela, AM | |
dc.contributor.wosstandard | WOS:Sendra, JR | |
dc.contributor.wosstandard | WOS:Lechuga, LM | |
dc.date.coverdate | Octubre 2006 | |
dc.identifier.conferenceid | events120524 | |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 2,331 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 11-09-2005 | - |
crisitem.event.eventsenddate | 14-09-2005 | - |
crisitem.author.dept | GIR IUIBS: Medicina Veterinaria e Investigación Terapéutica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos | - |
crisitem.author.dept | GIR IUMA: Equipos y Sistemas de Comunicación | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0002-2683-7592 | - |
crisitem.author.orcid | 0000-0002-9634-7871 | - |
crisitem.author.orcid | 0000-0001-5385-792X | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | Montoya Alonso, José Alberto | - |
crisitem.author.fullName | Medina Escuela, Alfonso Francisco | - |
crisitem.author.fullName | Sendra Sendra, José Ramón | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
60
checked on Mar 30, 2025
WEB OF SCIENCETM
Citations
52
checked on Mar 30, 2025
Page view(s)
69
checked on Sep 21, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.