dc.description.abstract | In this paper, a wind energy converter (WEC) model for the analysis of power fluctuations at an isolated wind plant is presented. The model includes the drive train dynamics, a first-order model for the asynchronous generator, and the power controller. The influence of each element is studied, and the conditions that can provoke oscillations in the power delivered by the WEC are considered. A set of measurements carried out during the setting of an isolated wind plant in the Canary Islands (Spain) is the basis for this study. In these measurements, an oscillatory behavior has been observed when wind speed was high. | |
dc.publisher | 0885-8969 | |
dc.relation.ispartof | IEEE Transactions on Energy Conversion | |
dc.source | IEEE Transactions on Energy Conversion[ISSN 0885-8969],v. 19, p. 217-221 | |
dc.subject.other | Turbine | |
dc.title | Power fluctuations in an isolated wind plant | |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1109/TEC.2003.822369 | |
dc.identifier.scopus | 1542375751 | |
dc.identifier.isi | 000189127600029 | |
dc.contributor.authorscopusid | 7006713401 | |
dc.contributor.authorscopusid | 6602563842 | |
dc.contributor.authorscopusid | 6602000039 | |
dc.contributor.authorscopusid | 7404493946 | |
dc.description.lastpage | 221 | |
dc.description.firstpage | 217 | |
dc.relation.volume | 19 | |
dc.type2 | Artículo | es |
dc.contributor.daisngid | 1326396 | |
dc.contributor.daisngid | 7717266 | |
dc.contributor.daisngid | 961582 | |
dc.contributor.daisngid | 14862531 | |
dc.contributor.wosstandard | WOS:Carrillo, C | |
dc.contributor.wosstandard | WOS:Feijoo, AE | |
dc.contributor.wosstandard | WOS:Cidras, J | |
dc.contributor.wosstandard | WOS:Gonzalez, J | |
dc.date.coverdate | Marzo 2004 | |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 0,722 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.orcid | 0009-0004-0826-0816 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | González Hernández,Jaime | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.