Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/51708
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abad, Cipriano | en_US |
dc.contributor.author | Urso, Stefano | en_US |
dc.contributor.author | Gomez, Elsa | en_US |
dc.contributor.author | De la Vega, Maria | en_US |
dc.date.accessioned | 2018-11-25T03:10:31Z | - |
dc.date.available | 2018-11-25T03:10:31Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 0966-8519 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/51708 | - |
dc.description.abstract | A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Heart Valve Disease | en_US |
dc.source | The Journal of heart valve disease[ISSN 0966-8519],v. 25(5), p. 634-637 (Septiembre 2016) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 321307 Cirugía del corazón | en_US |
dc.subject.other | Bioprosthesis | en_US |
dc.subject.other | Mitral valve | en_US |
dc.subject.other | Thrombosis | en_US |
dc.subject.other | Postoperative complications | en_US |
dc.title | Dysfunction of an On-X Heart Valve by Pannus | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.scopus | 85045548373 | - |
dc.contributor.authorscopusid | 7103043668 | - |
dc.contributor.authorscopusid | 14055297800 | - |
dc.contributor.authorscopusid | 57201651185 | - |
dc.contributor.authorscopusid | 17533652500 | - |
dc.description.lastpage | 637 | en_US |
dc.description.firstpage | 634 | en_US |
dc.relation.volume | 25 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 4 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Septiembre 2016 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 0,559 | - |
dc.description.sjrq | Q3 | - |
dc.description.scie | SCIE | - |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.orcid | 0000-0002-5088-2668 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Abad Vázquez,Cipriano Carlos | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
2
checked on Nov 17, 2024
Page view(s)
93
checked on Nov 9, 2024
Google ScholarTM
Check
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.