Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/50920
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Calbet, Jose A. L. | en_US |
dc.contributor.author | Boushel, Robert | en_US |
dc.contributor.other | Calbet, Jose A | - |
dc.date.accessioned | 2018-11-24T19:55:37Z | - |
dc.date.available | 2018-11-24T19:55:37Z | - |
dc.date.issued | 2015 | en_US |
dc.identifier.issn | 8750-7587 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/50920 | - |
dc.description.abstract | The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q˙ ) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q˙ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remains unknown if this technique is also accurate and reproducible during exercise. Sixteen healthy men underwent catheterization of the right femoral vein (for iced saline injection), an antecubital vein (ICG injection), and femoral artery (thermistor) to determine their Q˙ by TPTd and ICG concentration during incremental one- and two-legged pedaling on a cycle ergometer and combined arm cranking with leg pedaling to exhaustion. There was a close relationship between TPTd-Q˙ and ICG-Q˙ (r 0.95, n 151, standard error of the estimate: 1.452 l/min, P 0.001; mean difference of 0.06 l/min; limits of agreement 2.98 to 2.86 l/min), and TPTd-Q˙ and ICG-Q˙ increased linearly with oxygen uptake with similar intercepts and slopes. Both methods had mean coefficients of variation close to 5% for Q˙ , global end-diastolic volume, and intrathoracic blood volume. The mean coefficient of variation of EVLW, assessed with both indicators (ICG and thermal) was 17% and was sensitive enough to detect a reduction in EVLW of 107 ml when changing from resting supine to upright exercise. In summary, TPTd with bolus injection into the femoral vein is an accurate and reproducible method to assess Q˙ during exercise in humans. | en_US |
dc.language | eng | en_US |
dc.publisher | 8750-7587 | - |
dc.relation.ispartof | Journal of Applied Physiology | en_US |
dc.source | Journal Of Applied Physiology[ISSN 8750-7587],v. 118 (1), p. 1-10 | en_US |
dc.subject | 241106 Fisiología del ejercicio | en_US |
dc.subject.other | cardiac output | en_US |
dc.subject.other | indocyanine | en_US |
dc.subject.other | exercise | en_US |
dc.subject.other | thermodilution | en_US |
dc.subject.other | human | en_US |
dc.title | Assessment of cardiac output with transpulmonary thermodilution during exercise in humans | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1152/japplphysiol.00686.2014 | |
dc.identifier.scopus | 84920463516 | - |
dc.identifier.isi | 000347169000001 | - |
dcterms.isPartOf | Journal Of Applied Physiology | - |
dcterms.source | Journal Of Applied Physiology[ISSN 8750-7587],v. 118 (1), p. 1-10 | - |
dc.contributor.authorscopusid | 7004323423 | - |
dc.contributor.authorscopusid | 7003471688 | - |
dc.description.lastpage | 10 | - |
dc.description.firstpage | 1 | - |
dc.relation.volume | 118 | - |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000347169000001 | - |
dc.contributor.daisngid | 90295 | - |
dc.contributor.daisngid | 220476 | - |
dc.identifier.investigatorRID | H-6693-2015 | - |
dc.contributor.wosstandard | WOS:Calbet, JAL | |
dc.contributor.wosstandard | WOS:Boushel, R | |
dc.date.coverdate | Enero 2015 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 1,623 | |
dc.description.jcr | 3,004 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Educación Física | - |
crisitem.author.orcid | 0000-0002-9215-6234 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | López Calbet, José Antonio | - |
Colección: | Artículos |
Citas SCOPUSTM
12
actualizado el 24-nov-2024
Citas de WEB OF SCIENCETM
Citations
14
actualizado el 24-nov-2024
Visitas
79
actualizado el 08-jun-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.