Please use this identifier to cite or link to this item:
https://accedacris.ulpgc.es/jspui/handle/10553/49127
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hernandez, L. | en_US |
| dc.contributor.author | Hernandez, P. | en_US |
| dc.contributor.author | Sosa Ferrera, Z. | en_US |
| dc.date.accessioned | 2018-11-24T04:23:25Z | - |
| dc.date.available | 2018-11-24T04:23:25Z | - |
| dc.date.issued | 1988 | en_US |
| dc.identifier.issn | 0016-1152 | en_US |
| dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/49127 | - |
| dc.description.abstract | The determination of aniline by means of a carbon paste electrode (CPE) modified with 10% sepiolite was studied using differential pulse voltammetry. The best pre-concentration was achieved at pH 6.9 over 5 min and the bestip in the measuring cell was obtained at pH 1.5 using ΔE = 100 mV and a scan rate of 40 mV/s. Under these conditions detection limits (10 σ) of 15 ng/ ml were obtained. The method was applied to different beverages without the need for prior separation. | en_US |
| dc.language | eng | en_US |
| dc.publisher | 0016-1152 | - |
| dc.relation.ispartof | Fresenius Zeitschrift für Analytische Chemie | en_US |
| dc.source | Fresenius' Zeitschrift für Analytische Chemie [ISSN 0016-1152], v. 329, p. 756-759 | en_US |
| dc.subject | 2301 química analítica | en_US |
| dc.subject.other | Physical Chemistry | en_US |
| dc.subject.other | Analytical Chemistry | en_US |
| dc.subject.other | Inorganic Chemistry | en_US |
| dc.subject.other | Detection Limit | en_US |
| dc.subject.other | Aniline | en_US |
| dc.title | Differential pulse voltammetric determination of aniline with a carbon paste electrode modified by sepiolite | en_US |
| dc.type | info:eu-repo/semantics/article | es |
| dc.type | Article | es |
| dc.identifier.doi | 10.1007/BF00556910 | en_US |
| dc.identifier.scopus | 0043153666 | - |
| dc.contributor.authorscopusid | 55893844400 | - |
| dc.contributor.authorscopusid | 7202207055 | - |
| dc.contributor.authorscopusid | 6602897915 | - |
| dc.description.lastpage | 759 | - |
| dc.description.firstpage | 756 | - |
| dc.relation.volume | 329 | - |
| dc.investigacion | Ciencias | en_US |
| dc.type2 | Artículo | en_US |
| dc.utils.revision | Sí | en_US |
| dc.identifier.ulpgc | Sí | es |
| item.grantfulltext | none | - |
| item.fulltext | Sin texto completo | - |
| crisitem.author.dept | GIR IUNAT: Análisis Químico Medioambiental | - |
| crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
| crisitem.author.dept | Departamento de Química | - |
| crisitem.author.orcid | 0000-0003-3003-3607 | - |
| crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
| crisitem.author.fullName | Sosa Ferrera, María Zoraida | - |
| Appears in Collections: | Artículos | |
SCOPUSTM
Citations
17
checked on Jun 8, 2025
WEB OF SCIENCETM
Citations
19
checked on Feb 15, 2026
Page view(s)
261
checked on Jan 15, 2026
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.