Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/48952
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lopez, A. Santana | |
dc.contributor.author | Mirza-Rosca, J. | |
dc.contributor.author | Vasilescu, E. | |
dc.contributor.author | Drob, P. | |
dc.contributor.author | Raducanu, D. | |
dc.contributor.author | Angelescu, L. | |
dc.date.accessioned | 2018-11-24T02:30:02Z | - |
dc.date.available | 2018-11-24T02:30:02Z | - |
dc.date.issued | 2004 | |
dc.identifier.issn | 0254-0584 | |
dc.identifier.uri | http://hdl.handle.net/10553/48952 | - |
dc.description.abstract | The technical and functional characteristics of some biocompatible, thin, double-layer films (of different compositions; the first layer: Ag-30-Cr-70 or Co-30-Cr-70 alloy or stainless steel and the second layer: TiN) on rare-earth-based permanent magnet alloy (Nd-30-Dy-5-Fe-Al-0.4-B) proposed to be used as dental materials have been investigated. Data about electrochemical behaviour, wear resistance and adhesion are presented. The electrochemical behaviour of these films was determined in artificial saliva, using the electrochemical potentiostatic polarisation and electrochemical impedance spectroscopy techniques. The wear behaviour in different conditions of contact and load was tested and the adhesion was determined by scratching test. It resulted that the tested films presented passivation tendency and a very good stability, and no form of local corrosion was detected. The electrochemical behaviour of these films is described by an equivalent circuit with two time constants. The wear resistance is very good. The films own a very good adhesion, which is proper for the proposed purpose. (C) 2004 Elsevier B.V. All rights reserved. | |
dc.publisher | 0254-0584 | |
dc.relation.ispartof | Materials Chemistry and Physics | |
dc.source | Materials Chemistry and Physics[ISSN 0254-0584],v. 86, p. 38-43 | |
dc.subject.other | Titanium-Alloys | |
dc.subject.other | Surface | |
dc.title | Technical and functional properties of some biocompatible thin films | |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/j.matchemphys.2004.01.016 | |
dc.identifier.scopus | 2442683097 | |
dc.identifier.isi | 000221944300008 | |
dc.contributor.authorscopusid | 7401455226 | |
dc.contributor.authorscopusid | 6602582214 | |
dc.contributor.authorscopusid | 7003914522 | |
dc.contributor.authorscopusid | 6701624016 | |
dc.contributor.authorscopusid | 6602880475 | |
dc.contributor.authorscopusid | 6507970914 | |
dc.contributor.authorscopusid | 57190069840 | |
dc.description.lastpage | 43 | |
dc.description.firstpage | 38 | |
dc.relation.volume | 86 | |
dc.type2 | Artículo | es |
dc.contributor.daisngid | 7650393 | |
dc.contributor.daisngid | 6895390 | |
dc.contributor.daisngid | 222978 | |
dc.contributor.daisngid | 281703 | |
dc.contributor.daisngid | 602203 | |
dc.contributor.daisngid | 4831933 | |
dc.contributor.wosstandard | WOS:Lopez, AS | |
dc.contributor.wosstandard | WOS:Mirza-Rosca, J | |
dc.contributor.wosstandard | WOS:Vasilescu, E | |
dc.contributor.wosstandard | WOS:Drob, P | |
dc.contributor.wosstandard | WOS:Raducanu, D | |
dc.contributor.wosstandard | WOS:Angelescu, L | |
dc.date.coverdate | Julio 2004 | |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 1,113 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR Nanomaterials and Corrosion | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0003-0623-3318 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Mirza Rosca, Julia Claudia | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.