Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/48385
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Fernández Rodríguez, Ana María | en_US |
dc.contributor.author | Vega Díaz, Nicanor | en_US |
dc.contributor.author | Palop Cubillo, Leocadia | en_US |
dc.contributor.author | Baamonde Laborda, Eduardo | en_US |
dc.contributor.author | Morales Umpierrez, Adelaida | en_US |
dc.contributor.author | Pérez Borges, Patricia | en_US |
dc.contributor.author | Navarro Zurita, Manuel | en_US |
dc.contributor.author | Plaza Toledano, Celia | en_US |
dc.date.accessioned | 2018-11-23T21:15:44Z | - |
dc.date.available | 2018-11-23T21:15:44Z | - |
dc.date.issued | 1997 | en_US |
dc.identifier.issn | 0896-8608 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/48385 | - |
dc.description.abstract | Objectives: To compare the peritoneal clearances of urea and creatinine in continuous ambulatory peritoneal dialysis (CAPD) with three types of automated peritoneal dialysis (APD): continuous cycling peritoneal dialysis (CCPD), 50% tidal peritoneal dialysis (TPD), and 25% TPD and to assess the usefulness of the peritoneal equilibration test (PET) in predicting peritoneal clearances in overnight APD. Patients: Eleven uremic patients (mean age 44.5 +/- 15.45 years with a mean time on dialysis of 42.63 +/- 25.62 months) were included in the study. Measurements: PET for urea and creatinine following Twardowski's method. Peritoneal clearances for urea and creatinine CAPD: samples of blood and dialysate within 24 hours. APD: blood mean levels of urea and creatinine before and after nighttime dialysis. Dialysate: urea and creatinine in nocturnal and daytime dialysate. Results: Peritoneal clearance of creatinine was 38.14 +/- 9.99 L/week/1.73 m2 in CAPD, 44.28 +/- 12.4 L/week/1.73 m2 in CCPD, 50.07 +/- 17.86 L/week/1.73 m2 in 50% TPD (p < 0.05) and 40.18 +/- 6.65 L/week/1.73 m2 in 25% TPD. Peritoneal clearance of urea improved significantly in the three modalities of APD: 51.91 +/- 12.58 L/week/1.73 m2 in CAPD; 66.7 +/- 9.9 L/week/1.73 m2 in CCPD (p < 0.05); 76.3 +/- 14.5 L/week/1.73 m2 in 50% TPD (p < 0.001) and 64.4 +/- 11.4 L/week/1.73 m2 in 25% TPD (p < 0.05). The dialysate/ plasma (D/P) ratio of creatinine at 30, 60, 120, 180, and 240 minutes showed significant correlation with nighttime APD clearance. Nevertheless, only the D/P ratio of urea at 30, 60, and 120 minutes correlated with overnight APD clearance. Conclusions: A remarkable improvement was observed with APD regarding the clearance of urea mainly when 50% tidal peritoneal dialysis was used, whereas it was less noticeable in the clearance of creatinine. The PET is a helpful tool in predicting overnight peritoneal clearances of creatinine but it is less useful in predicting urea clearance. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Peritoneal Dialysis International | en_US |
dc.source | Peritoneal Dialysis International[ISSN 0896-8608],v. 17, p. 442-448 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3205 Medicina interna | en_US |
dc.subject.other | Creatinine | en_US |
dc.subject.other | Kidney | en_US |
dc.subject.other | Peritoneal dialysis | en_US |
dc.subject.other | Peritoneum | en_US |
dc.subject.other | Urea | en_US |
dc.title | Adequacy of dialysis in automated peritoneal dialysis: A clinical experience | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.scopus | 0030690980 | - |
dc.contributor.authorscopusid | 7005964329 | - |
dc.contributor.authorscopusid | 6507084608 | - |
dc.contributor.authorscopusid | 6507325150 | - |
dc.contributor.authorscopusid | 6504545615 | - |
dc.contributor.authorscopusid | 6505908446 | - |
dc.contributor.authorscopusid | 6507066030 | - |
dc.contributor.authorscopusid | 6504786372 | - |
dc.contributor.authorscopusid | 18034771800 | - |
dc.description.lastpage | 448 | en_US |
dc.description.firstpage | 442 | en_US |
dc.relation.volume | 17 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 7 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Septiembre-octubre 1997 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.jcr | 2,129 | - |
dc.description.jcrq | Q1 | - |
dc.description.scie | SCIE | - |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.fullName | Vega Díaz, Nicanor Jesús | - |
Colección: | Artículos |
Citas SCOPUSTM
15
actualizado el 17-nov-2024
Visitas
34
actualizado el 14-ene-2023
Google ScholarTM
Verifica
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.