Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/48382
Título: What is the link between poor ultrafiltration and increased mortality in anuric patients on automated peritoneal dialysis? Analysis of data from EAPOS
Autores/as: Davies, Simon J.
Brown, Edwina A.
Riegel, Werner
Clutterbuck, Elaine
Heimbürger, Olof
Vega Diaz, Nicanor 
Mellote, George J.
Perez-Contreras, Javier
Scanziani, Renzo
D'Auzac, Christian
Kuypers, Dirk
Divino Filho, Jose C.
Borras, M.
Brown, E.
Caillette-Beaudoin, A.
Ekstrand, A.
Frandsen, N. E.
Freida, P.
Friedrichsohn, C.
MacNamara, E.
Mactier, R.
Malmsten, G.
Mastrangelo, F.
Meeus, F.
Rodrigues, A. S.
Rodriguez-Carmona, A.
Rosman, J.
Rutherford, P.
Vychytil, A.
Weinreich, T.
Clasificación UNESCO: 32 Ciencias médicas
3205 Medicina interna
Palabras clave: Ultrafiltration
Solute transport
Blood pressure
Fluid status
Survival, et al.
Fecha de publicación: 2006
Publicación seriada: Peritoneal Dialysis International 
Resumen: Background: Primary analysis of the European Automated Peritoneal Dialysis Outcomes Study (EAPOS) found that patients with daily ultrafiltration (UF) below a predefined target of 750 mL at baseline experienced increased mortality and continuing low UF over 2 years. Setting: Multicenter, prospective observational study of prevalent, functionally anuric patients on automated peritoneal dialysis (APD) treated to predefined standards. Methods: Secondary data analysis to determine clinical covariates that might support a link between poor UF and outcome, including pattern of comorbidity, prescription, nutrition as determined by Subjective Global Assessment (SGA), membrane function, and blood pressure (BP). Ultrafiltration was treated as a categorical (comparing patients above and below target at baseline) and continuous dependent variable in univariate and multivariate regression. The relationship between BP and survival was also explored. Results: Of 177 patients recruited from 28 centers across Europe, 43 were below the UF target at baseline. Compared to those above target, there were no differences in the spread of comorbidity, type of APD prescription, SGA, BP, hemoglobin, HCO3, or parathyroid hormone, at baseline or at any later time. At baseline, plasma calcium and, at 12 months, plasma phosphate were lower in the low UF group. There was a weak positive correlation between baseline systolic or diastolic BP and UF, which remained on multivariate analysis but accounted for just 9% of the variability in BP. There was no clear relationship between baseline BP and survival, although, if anything, low BP was associated with earlier death. Poor UF was associated with lower mean dialysate glucose concentration during the first 4 months and with consistently worse membrane function. Conclusions: The increased mortality associated with poor UF is likely multifactorial and not easily explained by clear differences in comorbidity, nutritional state, or other indices of treatment at baseline. The lower plasma phosphate suggests a subsequent fall in appetite. Poor BP control is unlikely to be the explanation, and a link between lower BP, reduced UF, and earlier death is suggested. Failure to achieve adequate UF due to worse membrane function remains an important and potentially reversible or preventable cause.
URI: http://hdl.handle.net/10553/48382
ISSN: 0896-8608
Fuente: Peritoneal Dialysis International [ISSN 0896-8608], v. 26, p. 458-465
Colección:Artículos
Vista completa

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.