dc.description.abstractA study was carried out on a NaCl H2O RO thin film composite reverse osmosis membrane system to characterize these membranes, determine their performance and predict the effects of pressure and solute concentration in the feed using the correlation from the Kimura Sourirajan analysis. The effect of the solute concentration in the feed (0.0043-0.086 molal) operating at pressures of 500-2000 kPa was studied. The permeability constant, A, and the transport parameter D(Am)/kδ for CA 990 PP and HR 98 PP flat membranes were calculated and the results from both membranes were compared. The M20 lab unit had a total permeation surface of 0.72 m2 when all 20 membrane pairs were installed. During the experiments one pair of membranes was installed, resulting in a permeation surface of 0.036 m2. A study was carried out on a NaCl H2O RO thin film composite reverse osmosis membrane system to characterize these membranes, determine their performance and predict the effects of pressure and solute concentration in the feed using the correlation from the Kimura Sourirajan analysis. The effect of the solute concentration in the feed (0.0043-0.086 molal) operating at pressures of 500-2000 kPa was studied. The permeability constant, A, and the transport parameter DAm/kδ for CA 990 PP and HR 98 PP flat membranes were calculated and the results from both membranes were compared. The M20 lab unit had a total permeation surface of 0.72 m2 when all 20 membrane pairs were installed. During the experiments one pair of membranes was installed, resulting in a permeation surface of 0.036 m2.
dc.publisher0011-9164
dc.relation.ispartofDesalination (Amsterdam)
dc.sourceDesalination[ISSN 0011-9164],v. 126, p. 115-118
dc.titleTransport characterization in flat reverse osmosis membranes: Utilization of the Kimura-Sourirajan analysis method for the determination of mass transfer coefficient K, transport parameter D(am)/Kδ, and permeability constant A
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dc.typeConferenceObjectes
dc.relation.conferenceProceedings of the 1999 European Conference on Desalination and the Environment
dc.identifier.doi10.1016/S0011-9164(99)00162-9
dc.identifier.scopus0033226381
dc.contributor.authorscopusid6506805377
dc.contributor.authorscopusid6602105590
dc.contributor.authorscopusid6504256830
dc.description.lastpage118
dc.description.firstpage115
dc.relation.volume126
dc.type2Actas de congresoses
dc.date.coverdateNoviembre 1999
dc.identifier.conferenceidevents120263
dc.identifier.ulpgces
dc.description.jcr0,434
dc.description.jcrqQ3
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.event.eventsstartdate09-11-1999-
crisitem.event.eventsenddate12-11-1999-
crisitem.author.orcid0000-0003-3536-8481-
crisitem.author.fullNameGómez Gotor, Antonio-
Appears in Collections:Actas de congresos
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.