Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/48061
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Socorro, F. | en_US |
dc.contributor.author | Rodríguez De Rivera, M. | en_US |
dc.contributor.author | Jesus, Ch | en_US |
dc.date.accessioned | 2018-11-23T18:38:50Z | - |
dc.date.available | 2018-11-23T18:38:50Z | - |
dc.date.issued | 2001 | en_US |
dc.identifier.issn | 1418-2874 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/48061 | - |
dc.description.abstract | This work shows the difference between the results obtained in the electrical calibration and those corresponding to the chemical calibration in a TAM2277-204 flow-calorimeter by Thermometric. This difference is due to the fact that the mixture and the electrical dissipation do not occur in the same place. There are other additional aspects inherent to the mixture dissipation: the mixture does not take place instantaneously and extends in space. The physical model that has been calculated in this work explains the characteristics that are proper to a mixture dissipation and the effects of the injection in a qualitative and quantitative way. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Thermal Analysis and Calorimetry | en_US |
dc.source | Journal of Thermal Analysis and Calorimetry [ISSN 1418-2874], v. 64, p. 357-366 | en_US |
dc.subject | 2213 Termodinámica | en_US |
dc.subject | 220408 Líquidos | en_US |
dc.subject.other | Conduction calorimetry | en_US |
dc.subject.other | Flow calorimetry | en_US |
dc.subject.other | Liquid mixtures | en_US |
dc.subject.other | Modelling | en_US |
dc.subject.other | Signal processing | en_US |
dc.subject.other | Thermal measurement | en_US |
dc.title | A thermal model of a flow calorimeter | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | es |
dc.type | ConferenceObject | es |
dc.relation.conference | 12th ICTAC Congress | |
dc.relation.conference | 12th International Congress on Thermal Analysis and Calorimetry | |
dc.identifier.doi | 10.1023/A:1011582306796 | |
dc.identifier.scopus | 0034981231 | - |
dc.identifier.isi | 000167936000033 | |
dc.contributor.authorscopusid | 6603271349 | - |
dc.contributor.authorscopusid | 6506079738 | - |
dc.contributor.authorscopusid | 55391096600 | - |
dc.description.lastpage | 366 | - |
dc.description.firstpage | 357 | - |
dc.relation.volume | 64 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Actas de congresos | en_US |
dc.contributor.daisngid | 1486637 | |
dc.contributor.daisngid | 2312735 | |
dc.contributor.daisngid | 6018151 | |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Socorro, F | |
dc.contributor.wosstandard | WOS:de Rivera, M | |
dc.contributor.wosstandard | WOS:Jesus, C | |
dc.date.coverdate | Junio 2001 | |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.orcid | 0000-0002-4890-5947 | - |
crisitem.author.orcid | 0000-0002-6737-4096 | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.fullName | Socorro Lorenzo, Fabiola Lourdes | - |
crisitem.author.fullName | Rodríguez De Rivera Rodríguez, Manuel Jose M. | - |
Colección: | Actas de congresos |
Citas SCOPUSTM
25
actualizado el 02-mar-2025
Citas de WEB OF SCIENCETM
Citations
25
actualizado el 02-mar-2025
Visitas
111
actualizado el 30-nov-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.