Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/48055
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Socorro, F. | en_US |
dc.contributor.author | De Rivera, M. R. | en_US |
dc.date.accessioned | 2018-11-23T18:36:09Z | - |
dc.date.available | 2018-11-23T18:36:09Z | - |
dc.date.issued | 2005 | en_US |
dc.identifier.issn | 1388-6150 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/48055 | - |
dc.description.abstract | The effect of the injection velocity in the chemical calibration of a flow microcalorimeter is studied in this article. The experimental measures show a parabolic variation of the sensitivity in terms of the injection flow. The considered hypothesis is that the maximum of the sensitivity curve is produced when the spatial area in which the mixture dissipation takes place is centred with regard to the detector system. When increasing the injection flow, this mixture zone moves till it goes out of the detection area making the sensitivity diminish. It has been defined a time constant τmix which is related to the establishment time of the homogeneous mixture and with the length occupied by the mixture dissipation. A study has been carried out with three liquid mixtures that have different behaviours; within these mixtures, τmix has been determined in terms of the injection flow and the considered hypothesis has been confirmed. | en_US |
dc.language | eng | en_US |
dc.publisher | 1388-6150 | - |
dc.relation.ispartof | Journal of Thermal Analysis and Calorimetry | en_US |
dc.source | Journal of Thermal Analysis and Calorimetry [ISSN 1388-6150], v. 80, p. 763-767 | en_US |
dc.subject | 2213 Termodinámica | en_US |
dc.subject | 220408 Líquidos | en_US |
dc.subject.other | Sensitivity | en_US |
dc.subject.other | Liquid mixtures | en_US |
dc.subject.other | Flow microcalorimeter | en_US |
dc.subject.other | Chemical calibration | en_US |
dc.subject.other | Injection calorimeter | en_US |
dc.subject.other | Isothermal conduction calorimeter | en_US |
dc.title | Effect of the injection velocity on the spatial localization of the mixture dissipation in a flow microcalorimeter | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1007/s10973-005-0726-2 | |
dc.identifier.scopus | 21244480449 | - |
dc.identifier.isi | 000230670000036 | |
dc.contributor.authorscopusid | 6603271349 | - |
dc.contributor.authorscopusid | 6506079738 | - |
dc.description.lastpage | 767 | - |
dc.description.firstpage | 763 | - |
dc.relation.volume | 80 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 1486637 | |
dc.contributor.daisngid | 2312735 | |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Socorro, F | |
dc.contributor.wosstandard | WOS:de Rivera, MR | |
dc.date.coverdate | Junio 2005 | |
dc.identifier.ulpgc | Sí | es |
dc.description.jcr | 1,425 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.orcid | 0000-0002-4890-5947 | - |
crisitem.author.orcid | 0000-0002-6737-4096 | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.fullName | Socorro Lorenzo, Fabiola Lourdes | - |
crisitem.author.fullName | Rodríguez De Rivera Rodríguez, Manuel Jose M. | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.