Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47465
Campo DC Valoridioma
dc.contributor.authorRodriguez-Florido, Miguel A.en_US
dc.contributor.authorKrissian, Karlen_US
dc.contributor.authorRuiz-Alzola, Juanen_US
dc.contributor.authorWestin, Carl Fredriken_US
dc.date.accessioned2018-11-23T13:46:39Z-
dc.date.available2018-11-23T13:46:39Z-
dc.date.issued2001en_US
dc.identifier.isbn3540426973en_US
dc.identifier.issn0302-9743en_US
dc.identifier.urihttp://hdl.handle.net/10553/47465-
dc.description.abstractIn this paper, we compare two restoration techniques applied to 3D angiographies and to femoral CT scans. The first technique uses a Partial Derivative Equation and the second one is based on an extension of adaptive Wiener filters. We first present each method. Then, we discuss and compare the estimation of the local orientations in 3D images obtained either by the smoothed gradient and the principal curvature directions or by the eigenvectors of the structure tensor. A good estimation of the orientations is essential because it directs the restoration process. Finally, we compare the restored images on both synthetic and real images for the two studied applications.en_US
dc.languageengen_US
dc.relation.ispartofLecture Notes in Computer Scienceen_US
dc.sourceLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)[ISSN 0302-9743],v. 2208, p. 1031-1039en_US
dc.subject3314 Tecnología médicaen_US
dc.subject.otherReal Imageen_US
dc.subject.otherNoise imageen_US
dc.subject.otherStructure Tensoren_US
dc.subject.otherSynthetic Imageen_US
dc.subject.otherRestoration Techniqueen_US
dc.titleComparison of two restoration techniques in the context of 3D medical imagingen_US
dc.typeinfo:eu-repo/semantics/conferenceObjecten_US
dc.typeConferenceObjecten_US
dc.relation.conference4th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2001en_US
dc.identifier.doi10.1007/3-540-45468-3_123en_US
dc.identifier.scopus23044531145-
dc.contributor.authorscopusid55636952600-
dc.contributor.authorscopusid6507509943-
dc.contributor.authorscopusid6602218913-
dc.contributor.authorscopusid56614041800-
dc.contributor.authorscopusid35477140400-
dc.description.lastpage1039en_US
dc.description.firstpage1031en_US
dc.relation.volume2208en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Actas de congresosen_US
dc.utils.revisionen_US
dc.date.coverdateEnero 2001en_US
dc.identifier.conferenceidevents121288-
dc.identifier.ulpgces
dc.description.jcr0,415
dc.description.jcrqQ3
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.event.eventsstartdate14-10-2001-
crisitem.event.eventsenddate17-10-2001-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.orcid0000-0002-3545-2328-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameRuiz Alzola, Juan Bautista-
Colección:Actas de congresos
miniatura
Adobe PDF (402,56 kB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.