Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/47454
DC FieldValueLanguage
dc.contributor.authorCastaño-Moraga, J. A.en_US
dc.contributor.authorWestin, C. F.en_US
dc.contributor.authorRuiz-Alzola, J.en_US
dc.date.accessioned2018-11-23T13:41:42Z-
dc.date.available2018-11-23T13:41:42Z-
dc.date.issued2003en_US
dc.identifier.issn0302-9743en_US
dc.identifier.urihttp://hdl.handle.net/10553/47454-
dc.description.abstractThe performance of homomorphic processing cascade that guaranteed symmetric positive definite (PSD) tensor output in DT-MRI fields was discussed. DT-MRI fields measured the self-diffusion of water in biological tissue, and hence, tensors from these fields are PSD. The input subsystem to the homomorphic cascade computed the positive square root of the tensors. In order to describe the proposed cascade performance, white Guassian noise was added to synthetic tensor field, which was filtered using Wiener filter independently on each tensor component. The results show that the homomorphic cascade performs better than just filtering and projecting the filter output to guarantee PSD tensors.en_US
dc.languageengen_US
dc.relation.ispartofLecture Notes in Computer Scienceen_US
dc.sourceLecture Notes in Computer Science[ISSN 0302-9743],v. 2879, p. 990-991en_US
dc.subject3314 Tecnología médicaen_US
dc.subject.otherBiological Tissueen_US
dc.subject.otherNoise poweren_US
dc.subject.otherWiener filteren_US
dc.subject.otherHomomorphic Propertyen_US
dc.subject.otherTensor dataen_US
dc.titleHomomorphic filtering of DT-MRI fieldsen_US
dc.typeinfo:eu-repo/semantics/conferenceObjecten_US
dc.typeConferenceObjecten_US
dc.relation.conference6th International Conference on Medical Image Computing and Computer-Assisted Interventionen_US
dc.identifier.scopus0344392144-
dc.identifier.isi000188180400137-
dc.contributor.authorscopusid55666714400-
dc.contributor.authorscopusid35477140400-
dc.contributor.authorscopusid56614041800-
dc.description.lastpage991en_US
dc.description.firstpage990en_US
dc.relation.volume2879en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Actas de congresosen_US
dc.contributor.daisngid123122-
dc.contributor.daisngid47947-
dc.contributor.daisngid920778-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Moraga, CAC-
dc.contributor.wosstandardWOS:Westin, CF-
dc.contributor.wosstandardWOS:Ruiz-Alzola, J-
dc.date.coverdateDiciembre 2003en_US
dc.identifier.conferenceidevents120382-
dc.identifier.ulpgces
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.event.eventsstartdate15-11-2003-
crisitem.event.eventsenddate18-11-2003-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Señales y Comunicaciones-
crisitem.author.orcid0000-0002-3545-2328-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameRuiz Alzola, Juan Bautista-
Appears in Collections:Actas de congresos
Show simple item record

SCOPUSTM   
Citations

6
checked on Oct 13, 2024

WEB OF SCIENCETM
Citations

3
checked on Feb 25, 2024

Page view(s)

30
checked on May 4, 2024

Google ScholarTM

Check


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.