Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47454
Título: Homomorphic filtering of DT-MRI fields
Autores/as: Castaño-Moraga, J. A.
Westin, C. F.
Ruiz-Alzola, J. 
Clasificación UNESCO: 3314 Tecnología médica
Palabras clave: Biological Tissue
Noise power
Wiener filter
Homomorphic Property
Tensor data
Fecha de publicación: 2003
Publicación seriada: Lecture Notes in Computer Science 
Conferencia: 6th International Conference on Medical Image Computing and Computer-Assisted Intervention 
Resumen: The performance of homomorphic processing cascade that guaranteed symmetric positive definite (PSD) tensor output in DT-MRI fields was discussed. DT-MRI fields measured the self-diffusion of water in biological tissue, and hence, tensors from these fields are PSD. The input subsystem to the homomorphic cascade computed the positive square root of the tensors. In order to describe the proposed cascade performance, white Guassian noise was added to synthetic tensor field, which was filtered using Wiener filter independently on each tensor component. The results show that the homomorphic cascade performs better than just filtering and projecting the filter output to guarantee PSD tensors.
URI: http://hdl.handle.net/10553/47454
ISSN: 0302-9743
Fuente: Lecture Notes in Computer Science[ISSN 0302-9743],v. 2879, p. 990-991