Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/47454
Título: | Homomorphic filtering of DT-MRI fields | Autores/as: | Castaño-Moraga, J. A. Westin, C. F. Ruiz-Alzola, J. |
Clasificación UNESCO: | 3314 Tecnología médica | Palabras clave: | Biological Tissue Noise power Wiener filter Homomorphic Property Tensor data |
Fecha de publicación: | 2003 | Publicación seriada: | Lecture Notes in Computer Science | Conferencia: | 6th International Conference on Medical Image Computing and Computer-Assisted Intervention | Resumen: | The performance of homomorphic processing cascade that guaranteed symmetric positive definite (PSD) tensor output in DT-MRI fields was discussed. DT-MRI fields measured the self-diffusion of water in biological tissue, and hence, tensors from these fields are PSD. The input subsystem to the homomorphic cascade computed the positive square root of the tensors. In order to describe the proposed cascade performance, white Guassian noise was added to synthetic tensor field, which was filtered using Wiener filter independently on each tensor component. The results show that the homomorphic cascade performs better than just filtering and projecting the filter output to guarantee PSD tensors. | URI: | http://hdl.handle.net/10553/47454 | ISSN: | 0302-9743 | Fuente: | Lecture Notes in Computer Science[ISSN 0302-9743],v. 2879, p. 990-991 |
Colección: | Actas de congresos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.