Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/47437
DC Field | Value | Language |
---|---|---|
dc.contributor.author | De Luis-García, R. | en_US |
dc.contributor.author | Tristán-Vega, A. | en_US |
dc.contributor.author | Alberola-López, Carlos | en_US |
dc.contributor.author | Ruiz-Alzola, Juan | en_US |
dc.contributor.author | Sosa Cabrera,Darío | en_US |
dc.date.accessioned | 2018-11-23T13:33:57Z | - |
dc.date.available | 2018-11-23T13:33:57Z | - |
dc.date.issued | 2008 | en_US |
dc.identifier.isbn | 9780819471048 | en_US |
dc.identifier.issn | 1605-7422 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/47437 | - |
dc.description.abstract | Elastography, an ultrasound modality based on the relation between tissue strain and its mechanical properties, has a strong potential in the diagnosis and prognosis of tumors. For instance, tissue affected by breast and prostate cancer undergoes a change in its elastic properties. These changes can be measured using ultrasound signals. The standard way to visualize the elastic properties of tissues in elastography is the representation of the axial strain. Other approaches investigate the information contained in shear strain elastograms, vorticity or the representation of the full strain tensor. In this paper, we propose to represent the elastic behaviour of tissues through the visualization of the Strain Index, related with the trace of the strain tensor. Based on the mathematical interpretation of the strain tensor, this novel parameter is equivalent to the sum of the eigenvalues of the strain tensor, and constitutes a measure of the total amount of strain of the soft tissue. In order to show the potential of this visualization approach, a tissue-mimicking phantom was modeled as a 10×10×5 cm region containing a centered 10mm cylindrical inclusion three times stiffer than the surrounding material, and its elastic behavior was simulated using finite elements software. Synthetic pre- and post-compression (1.25%) B-mode images were computer-generated with ultrasound simulator. Results show that the visualization of the tensor trace significantly improves the representation and detection of inclusions, and can help add insight in the detection of different types of tumors. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Progress in Biomedical Optics and Imaging - Proceedings of SPIE | en_US |
dc.source | Progress in Biomedical Optics and Imaging - Proceedings of SPIE[ISSN 1605-7422],v. 6920 (69200W) | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.subject.other | Ultrasound Elastography | en_US |
dc.subject.other | Breast-Lesions | en_US |
dc.subject.other | Tissues | en_US |
dc.subject.other | Elastography | en_US |
dc.subject.other | Elasticity Imaging | en_US |
dc.subject.other | Elastogram | en_US |
dc.subject.other | Strain | en_US |
dc.subject.other | Trace | en_US |
dc.subject.other | Medical Imaging | en_US |
dc.subject.other | Ultrasound | en_US |
dc.subject.other | Optical Flow | en_US |
dc.title | Strain index: A New visualizing parameter for US elastography | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | Medical Imaging 2008: Ultrasonic Imaging and Signal Processing | en_US |
dc.identifier.doi | 10.1117/12.769191 | en_US |
dc.identifier.scopus | 42949160045 | - |
dc.identifier.isi | 000256176100028 | - |
dc.contributor.authorscopusid | 22635901300 | - |
dc.contributor.authorscopusid | 6506938417 | - |
dc.contributor.authorscopusid | 24073935500 | - |
dc.contributor.authorscopusid | 55999734500 | - |
dc.contributor.authorscopusid | 56614041800 | - |
dc.identifier.eissn | 1996-756X | - |
dc.identifier.issue | 69200W | - |
dc.relation.volume | 6920 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.contributor.daisngid | 3819802 | - |
dc.contributor.daisngid | 1226637 | - |
dc.contributor.daisngid | 1159839 | - |
dc.contributor.daisngid | 2978308 | - |
dc.contributor.daisngid | 920778 | - |
dc.description.numberofpages | 8 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Sosa-Cabrera, D | - |
dc.contributor.wosstandard | WOS:de Luis-Garcia, R | - |
dc.contributor.wosstandard | WOS:Tristan-Vega, A | - |
dc.contributor.wosstandard | WOS:Alberola-Lopez, C | - |
dc.contributor.wosstandard | WOS:Ruiz-Alzola, J | - |
dc.date.coverdate | Mayo 2008 | en_US |
dc.identifier.conferenceid | events121338 | - |
dc.identifier.ulpgc | Sí | es |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.event.eventsstartdate | 17-02-2008 | - |
crisitem.event.eventsenddate | 18-02-2008 | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-3545-2328 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Ruiz Alzola, Juan Bautista | - |
crisitem.author.fullName | Sosa Cabrera,Darío | - |
Appears in Collections: | Actas de congresos |
Page view(s)
74
checked on Aug 10, 2024
Download(s)
147
checked on Aug 10, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.