Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/47126
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Plíšek, Jiří | en_US |
dc.contributor.author | Krčmová, Lenka Kujovská | en_US |
dc.contributor.author | Aufartová, Jana | en_US |
dc.contributor.author | Morales, Tanausú V. | en_US |
dc.contributor.author | Esponda, Sarah M. | en_US |
dc.contributor.author | Oros, Roman | en_US |
dc.contributor.author | Kasalová, Eva | en_US |
dc.contributor.author | Santana-Rodriguez, Jose J. | en_US |
dc.contributor.author | Sobotka, Luboš | en_US |
dc.contributor.author | Solich, Petr | en_US |
dc.contributor.author | Solichová, Dagmar | en_US |
dc.date.accessioned | 2018-11-23T11:03:14Z | - |
dc.date.available | 2018-11-23T11:03:14Z | - |
dc.date.issued | 2013 | en_US |
dc.identifier.issn | 1615-9306 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/47126 | - |
dc.description.abstract | Biomarkers, 25‐hydroxyvitamin D3 and 25‐hydroxyvitamin D2, are important indicators of the vitamin D general status and are monitored in several pathophysiological disorders, such as osteoporosis, diabetes, heart disease, etc. A novel ultra‐HPLC with MS/MS methodology for the analysis of 25‐hydroxyvitamin D derivatives coupled with a very simple and highly rapid sample preparation step was developed. Analytical parameters obtained showed linearity (R2) above 0.999 for both vitamins with accuracies between 95.8 and 102%. The LODs were as low as 0.22 and 0.67 nmol/L for 25‐hydroxyvitamin D3 and 25‐hydroxyvitamin D2, respectively. Intra‐assay precision (%RSD) was lower than 4.5%, and inter‐assay precision (%RSD) was lower than 6.5%. The feasibility of the developed methodology to be applied in clinical routine analysis has been proved by its application in blood samples from non‐agenarian patients, patients with familial hypercholesterolemia and patients suffering from age‐related macular degeneration. | en_US |
dc.language | eng | en_US |
dc.publisher | 1615-9306 | - |
dc.relation.ispartof | Journal of Separation Science | en_US |
dc.source | Journal of Separation Science [ISSN 1615-9306], v. 36, p. 3702-3708 | en_US |
dc.subject | 2301 química analítica | en_US |
dc.subject.other | Clinical research | en_US |
dc.subject.other | Mass spectrometry | en_US |
dc.subject.other | Standard reference material 972 | en_US |
dc.subject.other | Vitamin D | en_US |
dc.title | New approach for the clinical monitoring of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by ultra high performance liquid chromatography with MS/MS based on the standard reference material 972 | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1002/jssc.201300553 | |
dc.identifier.scopus | 84889643059 | - |
dc.identifier.isi | 000327556300008 | |
dc.contributor.authorscopusid | 36127932200 | - |
dc.contributor.authorscopusid | 15071897900 | - |
dc.contributor.authorscopusid | 36187944300 | - |
dc.contributor.authorscopusid | 36454811400 | - |
dc.contributor.authorscopusid | 57201412739 | - |
dc.contributor.authorscopusid | 55955016100 | - |
dc.contributor.authorscopusid | 55954992500 | - |
dc.contributor.authorscopusid | 56248783900 | - |
dc.contributor.authorscopusid | 7005048316 | - |
dc.contributor.authorscopusid | 7003997787 | - |
dc.contributor.authorscopusid | 6701818464 | - |
dc.description.lastpage | 3708 | - |
dc.description.firstpage | 3702 | - |
dc.relation.volume | 36 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 2102416 | |
dc.contributor.daisngid | 524355 | |
dc.contributor.daisngid | 3089112 | |
dc.contributor.daisngid | 30794982 | |
dc.contributor.daisngid | 23299015 | |
dc.contributor.daisngid | 30773546 | |
dc.contributor.daisngid | 6396191 | |
dc.contributor.daisngid | 10914640 | |
dc.contributor.daisngid | 371672 | |
dc.contributor.daisngid | 88909 | |
dc.contributor.daisngid | 193151 | |
dc.contributor.wosstandard | WOS:Plisek, J | |
dc.contributor.wosstandard | WOS:Krcmova, LK | |
dc.contributor.wosstandard | WOS:Aufartova, J | |
dc.contributor.wosstandard | WOS:Morales, TV | |
dc.contributor.wosstandard | WOS:Esponda, SM | |
dc.contributor.wosstandard | WOS:Oros, R | |
dc.contributor.wosstandard | WOS:Kasalova, E | |
dc.contributor.wosstandard | WOS:Santana-Rodriguez, JJ | |
dc.contributor.wosstandard | WOS:Sobotka, L | |
dc.contributor.wosstandard | WOS:Solich, P | |
dc.contributor.wosstandard | WOS:Solichova, D | |
dc.date.coverdate | Diciembre 2013 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 1,119 | |
dc.description.jcr | 2,594 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUNAT: Análisis Químico Medioambiental | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.dept | GIR IUNAT: Análisis Químico Medioambiental | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.orcid | 0000-0001-9872-5293 | - |
crisitem.author.orcid | 0000-0002-5635-7215 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Montesdeoca Esponda, Sarah | - |
crisitem.author.fullName | Santana Rodríguez, José Juan | - |
Colección: | Artículos |
Citas SCOPUSTM
11
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
10
actualizado el 17-nov-2024
Visitas
79
actualizado el 13-ene-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.