dc.description.abstractIn this paper, a demonstrator of three different elements of the EU FET HELICoiD project is introduced. The goal of this demonstration is to show how the combination of hyperspectral imaging and machine learning can be a potential solution to precise real-time detection of tumor tissues during surgical operations. The HELICoiD setup consists of two hyperspectral cameras, a scanning unit, an illumination system, a data processing system and an EMB01 accelerator platform, which hosts an MPPA-256 manycore chip. All the components are mounted fulfilling restrictions from surgical environments, as shown in the accompanying video recorded at the operating room. An in-vivo human brain hyperspectral image data base, obtained at the University Hospital Doctor Negrin in Las Palmas de Gran Canaria, has been employed as input to different supervised classification algorithms (SVM, RF, NN) and to a spatial-spectral filtering stage (SVM-KNN). The resulting classification maps are shown in this demo. In addition, the implementation of the SVM-KNN classification algorithm on the MPPA EMB01 platform is demonstrated in the live demo.-
dc.languageeng-
dc.relation.ispartofConference on Design and Architectures for Signal and Image Processing, DASIP-
dc.sourceConference on Design and Architectures for Signal and Image Processing, DASIP[ISSN 2164-9766] (7853831), p. 237-238-
dc.subject3307 Tecnología electrónica-
dc.subject.otherHyperspectral imaging-
dc.subject.otherTumors-
dc.subject.otherSurgery-
dc.subject.otherCancer-
dc.subject.otherReal-time systems-
dc.titleDemo: HELICoiD tool demonstrator for real-time brain cancer detection-
dc.typeinfo:eu-repo/semantics/conferenceObject-
dc.typeConferenceObject-
dc.relation.conference2016 Conference on Design and Architectures for Signal and Image Processing, DASIP 2016-
dc.identifier.doi10.1109/DASIP.2016.7853831-
dc.identifier.scopus85014435265-
dc.identifier.isi000405720300035-
dc.contributor.authorscopusid23005852100-
dc.contributor.authorscopusid56405568500-
dc.contributor.authorscopusid57192839213-
dc.contributor.authorscopusid57189334144-
dc.contributor.authorscopusid57192829417-
dc.contributor.authorscopusid56006321500-
dc.contributor.authorscopusid36447485600-
dc.contributor.authorscopusid7006751614-
dc.description.lastpage238-
dc.identifier.issue7853831-
dc.description.firstpage237-
dc.investigacionIngeniería y Arquitectura-
dc.type2Actas de congresos-
dc.contributor.daisngid1888017-
dc.contributor.daisngid2096372-
dc.contributor.daisngid3634522-
dc.contributor.daisngid1812298-
dc.contributor.daisngid3360488-
dc.contributor.daisngid506422-
dc.contributor.daisngid693458-
dc.contributor.daisngid384271-
dc.description.numberofpages2-
dc.identifier.eisbn979-1-0922-7915-3-
dc.utils.revision-
dc.contributor.wosstandardWOS:Salvador, R-
dc.contributor.wosstandardWOS:Fabelo, H-
dc.contributor.wosstandardWOS:Lazcano, R-
dc.contributor.wosstandardWOS:Ortega, S-
dc.contributor.wosstandardWOS:Madronal, D-
dc.contributor.wosstandardWOS:Callic, GM-
dc.contributor.wosstandardWOS:Juarez, E-
dc.contributor.wosstandardWOS:Sanz, C-
dc.date.coverdateJulio 2016-
dc.identifier.conferenceidevents121055-
dc.identifier.ulpgces
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.event.eventsstartdate12-10-2016-
crisitem.event.eventsenddate14-10-2016-
crisitem.author.deptGIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.deptGIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.deptGIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.orcid0000-0002-9794-490X-
crisitem.author.orcid0000-0002-7519-954X-
crisitem.author.orcid0000-0002-3784-5504-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.fullNameFabelo Gómez, Himar Antonio-
crisitem.author.fullNameOrtega Sarmiento,Samuel-
crisitem.author.fullNameMarrero Callicó, Gustavo Iván-
Appears in Collections:Actas de congresos
Thumbnail
Adobe PDF (382,81 kB)
Show simple item record

SCOPUSTM   
Citations

4
checked on Nov 24, 2024

WEB OF SCIENCETM
Citations

3
checked on Feb 25, 2024

Page view(s)

118
checked on Aug 3, 2024

Download(s)

189
checked on Aug 3, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.