Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/46685
Campo DC Valoridioma
dc.contributor.authorSole Violan, Jorgeen_US
dc.contributor.authorDe Castro, F. R.en_US
dc.contributor.authorLuna, J. C.en_US
dc.contributor.authorBenitez, A. B.en_US
dc.contributor.authorAlonso, J. L.M.en_US
dc.date.accessioned2018-11-23T07:03:51Z-
dc.date.available2018-11-23T07:03:51Z-
dc.date.issued1993en_US
dc.identifier.issn0012-3692en_US
dc.identifier.urihttp://hdl.handle.net/10553/46685-
dc.description.abstractThe relative efficacy of telescoping plugged catheter (TPC) and bronchoalveolar lavage (BAL) in the diagnosis of pneumonia in mechanically ventilated patients has been compared in 45 subjects suspected of having pneumonia because of the presence of clinical and radiographic criteria. Diagnosis of pneumonia was strongly suggested in 25 of the 45 patients, and definitely confirmed in 10 of them. The diagnostic threshold to assess a quantitative bacterial culture as positive was a growth on BAL of greater-than-or-equal-to 10(5) cfu/ml and on TPC of greater-than-or-equal-to 10(3) cfu/ml. The BAL, specimen cultures established the diagosis in 19 cases (76 percent). In the remaining six patients, this technique did not permit the assessment of the diagnosis, which was established by other procedures (TPC, blood cultures, clinical outcome, or autopsy). False-positive results were not found. Sensitivity and specificity for BAL cultures were 76 percent and 100 percent, respectively. Telescoping plugged catheter established the presence of pneumonia in 16 patients (64 percent). Combining both techniques, the sensitivity increased up to 88 percent, maintaining specificity of 100 percent. In summary, BAL has a greater sensitivity than TPC in the diagnosis of pneumonias in mechanically ventilated patients. However, they are procedures that can complement each other.en_US
dc.languageengen_US
dc.relation.ispartofChest (American College of Chest Physicians)en_US
dc.sourceChest[ISSN 0012-3692],v. 103, p. 386-390en_US
dc.subject32 Ciencias médicasen_US
dc.subject3205 Medicina internaen_US
dc.subject320508 Enfermedades pulmonaresen_US
dc.subject.otherPneumoniaen_US
dc.subject.otherBronchoalveolar lavageen_US
dc.subject.otherCatheteren_US
dc.subject.otherMechanically ventilated patientsen_US
dc.titleComparative efficacy of bronchoalveolar lavage and telescoping plugged catheter in the diagnosis of pneumonia in mechanically ventilated patientsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1378/chest.103.2.386en_US
dc.identifier.scopus0027408816-
dc.identifier.isiA1993KL71200016-
dc.contributor.authorscopusid7801493602-
dc.contributor.authorscopusid55942667000-
dc.contributor.authorscopusid7005926186-
dc.contributor.authorscopusid36338524500-
dc.contributor.authorscopusid57197099864-
dc.description.lastpage390en_US
dc.description.firstpage386en_US
dc.relation.volume103en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid3159318-
dc.contributor.daisngid464249-
dc.contributor.daisngid9335430-
dc.contributor.daisngid4740016-
dc.contributor.daisngid3184179-
dc.description.numberofpages5en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:VIOLAN, JS-
dc.contributor.wosstandardWOS:DECASTRO, FR-
dc.contributor.wosstandardWOS:LUNA, JC-
dc.contributor.wosstandardWOS:BENITEZ, AB-
dc.contributor.wosstandardWOS:ALONSO, JLM-
dc.date.coverdateFebrero 1993en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.deptGIR IUIBS: Patología y Tecnología médica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-0483-4470-
crisitem.author.orcid0000-0002-6812-2739-
crisitem.author.orcid0000-0002-2931-9483-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameSole Violan,Jorge-
crisitem.author.fullNameRodríguez De Castro, Felipe Carlos B.-
crisitem.author.fullNameCaminero Luna, José Antonio-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.