Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/46685
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Sole Violan, Jorge | en_US |
dc.contributor.author | De Castro, F. R. | en_US |
dc.contributor.author | Luna, J. C. | en_US |
dc.contributor.author | Benitez, A. B. | en_US |
dc.contributor.author | Alonso, J. L.M. | en_US |
dc.date.accessioned | 2018-11-23T07:03:51Z | - |
dc.date.available | 2018-11-23T07:03:51Z | - |
dc.date.issued | 1993 | en_US |
dc.identifier.issn | 0012-3692 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/46685 | - |
dc.description.abstract | The relative efficacy of telescoping plugged catheter (TPC) and bronchoalveolar lavage (BAL) in the diagnosis of pneumonia in mechanically ventilated patients has been compared in 45 subjects suspected of having pneumonia because of the presence of clinical and radiographic criteria. Diagnosis of pneumonia was strongly suggested in 25 of the 45 patients, and definitely confirmed in 10 of them. The diagnostic threshold to assess a quantitative bacterial culture as positive was a growth on BAL of greater-than-or-equal-to 10(5) cfu/ml and on TPC of greater-than-or-equal-to 10(3) cfu/ml. The BAL, specimen cultures established the diagosis in 19 cases (76 percent). In the remaining six patients, this technique did not permit the assessment of the diagnosis, which was established by other procedures (TPC, blood cultures, clinical outcome, or autopsy). False-positive results were not found. Sensitivity and specificity for BAL cultures were 76 percent and 100 percent, respectively. Telescoping plugged catheter established the presence of pneumonia in 16 patients (64 percent). Combining both techniques, the sensitivity increased up to 88 percent, maintaining specificity of 100 percent. In summary, BAL has a greater sensitivity than TPC in the diagnosis of pneumonias in mechanically ventilated patients. However, they are procedures that can complement each other. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Chest (American College of Chest Physicians) | en_US |
dc.source | Chest[ISSN 0012-3692],v. 103, p. 386-390 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3205 Medicina interna | en_US |
dc.subject | 320508 Enfermedades pulmonares | en_US |
dc.subject.other | Pneumonia | en_US |
dc.subject.other | Bronchoalveolar lavage | en_US |
dc.subject.other | Catheter | en_US |
dc.subject.other | Mechanically ventilated patients | en_US |
dc.title | Comparative efficacy of bronchoalveolar lavage and telescoping plugged catheter in the diagnosis of pneumonia in mechanically ventilated patients | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1378/chest.103.2.386 | en_US |
dc.identifier.scopus | 0027408816 | - |
dc.identifier.isi | A1993KL71200016 | - |
dc.contributor.authorscopusid | 7801493602 | - |
dc.contributor.authorscopusid | 55942667000 | - |
dc.contributor.authorscopusid | 7005926186 | - |
dc.contributor.authorscopusid | 36338524500 | - |
dc.contributor.authorscopusid | 57197099864 | - |
dc.description.lastpage | 390 | en_US |
dc.description.firstpage | 386 | en_US |
dc.relation.volume | 103 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 3159318 | - |
dc.contributor.daisngid | 464249 | - |
dc.contributor.daisngid | 9335430 | - |
dc.contributor.daisngid | 4740016 | - |
dc.contributor.daisngid | 3184179 | - |
dc.description.numberofpages | 5 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:VIOLAN, JS | - |
dc.contributor.wosstandard | WOS:DECASTRO, FR | - |
dc.contributor.wosstandard | WOS:LUNA, JC | - |
dc.contributor.wosstandard | WOS:BENITEZ, AB | - |
dc.contributor.wosstandard | WOS:ALONSO, JLM | - |
dc.date.coverdate | Febrero 1993 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-0483-4470 | - |
crisitem.author.orcid | 0000-0002-6812-2739 | - |
crisitem.author.orcid | 0000-0002-2931-9483 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Sole Violan,Jorge | - |
crisitem.author.fullName | Rodríguez De Castro, Felipe Carlos B. | - |
crisitem.author.fullName | Caminero Luna, José Antonio | - |
Colección: | Artículos |
Citas SCOPUSTM
49
actualizado el 24-nov-2024
Citas de WEB OF SCIENCETM
Citations
36
actualizado el 24-nov-2024
Visitas
98
actualizado el 17-ago-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.