Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/46393
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ruiz-García, A. | en_US |
dc.contributor.author | Ruiz-Saavedra, E. | en_US |
dc.contributor.author | Pérez-Báez, S. O. | en_US |
dc.contributor.author | González-González, J. E. | en_US |
dc.contributor.other | Ruiz Garcia, Alejandro | - |
dc.date.accessioned | 2018-11-23T04:10:53Z | - |
dc.date.available | 2018-11-23T04:10:53Z | - |
dc.date.issued | 2015 | en_US |
dc.identifier.issn | 1944-3994 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/46393 | - |
dc.description.abstract | The RO brackish water desalination plant described in this paper has been operating from June 2004 without using acid in the pretreatment and only using antiscalants during 75.000 h with the same RO elements. The present research describes the graphical evolution of the operating information of the first nine years. A study of the normalization and standardization of the information about the nine years of evolution of the plant for fixed feedwater conditions, operating pressure, and system recovery are also shown, so that the performance evaluation of the plant can be indicated correctly. From these results it has been deduced the compaction and fouling factor values, and the average ionic permeability coefficients of the RO membrane utilized. Likewise, this paper describes the graphic evolution of the brine Langelier saturation index and Stiff and Davis stability index (actual and theoric values). The conclusions of this study and the operating experience are intended to get a practical and optimum design of RO brackish water desalination plants without using acid in the pretreatment and having a reasonable operating life between 9 and 10 years. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Desalination and Water Treatment | en_US |
dc.source | Desalination and Water Treatment [ISSN 1944-3994], v. 55 (9), p. 2555-2561 | en_US |
dc.subject | 3308 Ingeniería y tecnología del medio ambiente | en_US |
dc.subject | 330806 Regeneración del agua | en_US |
dc.subject.other | Brackish water | en_US |
dc.subject.other | Reverse osmosis | en_US |
dc.subject.other | Desalination plants | en_US |
dc.subject.other | Operating data | en_US |
dc.subject.other | Normalization | en_US |
dc.title | Evaluation of the first nine years operating data of a RO brackish water desalination plant in Las Palmas, Canary Islands, Spain | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.relation.conference | Conference on Desalination for the Environment - Clean Water and Energy | |
dc.identifier.doi | 10.1080/19443994.2014.939485 | |
dc.identifier.scopus | 84939651487 | - |
dc.identifier.isi | 000377971200029 | - |
dcterms.isPartOf | Desalination And Water Treatment | - |
dcterms.source | Desalination And Water Treatment[ISSN 1944-3994],v. 55 (9), p. 2555-2561 | - |
dc.contributor.authorscopusid | 55749145800 | - |
dc.contributor.authorscopusid | 56092031900 | - |
dc.contributor.authorscopusid | 6506878715 | - |
dc.contributor.authorscopusid | 57212058190 | |
dc.contributor.authorscopusid | 7006242436 | - |
dc.description.lastpage | 2561 | - |
dc.description.firstpage | 2555 | - |
dc.relation.volume | 55 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000377971200029 | - |
dc.contributor.daisngid | 2368242 | - |
dc.contributor.daisngid | 5510440 | - |
dc.contributor.daisngid | 8775834 | - |
dc.contributor.daisngid | 1240221 | |
dc.contributor.daisngid | 18981638 | - |
dc.identifier.investigatorRID | M-3697-2014 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Ruiz-Garcia, A | |
dc.contributor.wosstandard | WOS:Ruiz-Saavedra, E | |
dc.contributor.wosstandard | WOS:Perez-Baez, SO | |
dc.contributor.wosstandard | WOS:Gonzalez-Gonzalez, JE | |
dc.date.coverdate | Enero 2015 | |
dc.identifier.conferenceid | events120957 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,385 | |
dc.description.jcr | 1,272 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.event.eventsstartdate | 11-05-2014 | - |
crisitem.event.eventsenddate | 15-05-2014 | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.orcid | 0000-0002-5209-653X | - |
crisitem.author.orcid | 0000-0002-6909-0759 | - |
crisitem.author.orcid | 0000-0001-6644-0226 | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Ruiz García, Alejandro | - |
crisitem.author.fullName | Pérez Báez,Sebastián Ovidio | - |
crisitem.author.fullName | González González,Juan Emilio | - |
Appears in Collections: | Artículos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.