Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/45507
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hernández-Morera, Pablo | en_US |
dc.contributor.author | Castaño-González, Irene | en_US |
dc.contributor.author | Travieso-González, Carlos M. | en_US |
dc.contributor.author | Mompeó Corredera, Blanca Rosa | en_US |
dc.contributor.author | Ortega-Santana, Francisco | en_US |
dc.date.accessioned | 2018-11-22T10:23:11Z | - |
dc.date.available | 2018-11-22T10:23:11Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 1932-6203 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/45507 | - |
dc.description.abstract | Purpose To develop a digital image processing method to quantify structural components (smooth muscle fibers and extracellular matrix) in the vessel wall stained with Masson’s trichrome, and a statistical method suitable for small sample sizes to analyze the results previously obtained. Methods The quantification method comprises two stages. The pre-processing stage improves tissue image appearance and the vessel wall area is delimited. In the feature extraction stage, the vessel wall components are segmented by grouping pixels with a similar color. The area of each component is calculated by normalizing the number of pixels of each group by the vessel wall area. Statistical analyses are implemented by permutation tests, based on resampling without replacement from the set of the observed data to obtain a sampling distribution of an estimator. The implementation can be parallelized on a multicore machine to reduce execution time. Results The methods have been tested on 48 vessel wall samples of the internal saphenous vein stained with Masson’s trichrome. The results show that the segmented areas are consistent with the perception of a team of doctors and demonstrate good correlation between the expert judgments and the measured parameters for evaluating vessel wall changes. Conclusion The proposed methodology offers a powerful tool to quantify some components of the vessel wall. It is more objective, sensitive and accurate than the biochemical and qualitative methods traditionally used. The permutation tests are suitable statistical techniques to analyze the numerical measurements obtained when the underlying assumptions of the other statistical techniques are not met. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | PLoS ONE | en_US |
dc.source | PLoS ONE [ISSN 1932-6203],v. 11 (1), e0146954 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 240401 Bioestadística | en_US |
dc.subject.other | Masson's Trichrome | en_US |
dc.subject.other | Smooth muscle | en_US |
dc.subject.other | Digital image proceesing | en_US |
dc.subject.other | Estimation theory | en_US |
dc.title | Quantification and statistical analysis methods for vessel wall components from stained images with Masson's trichrome | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1371/journal.pone.0146954 | en_US |
dc.identifier.scopus | 2-s2.0-84955308846 | - |
dc.contributor.authorscopusid | 36782546400 | - |
dc.contributor.authorscopusid | 57073688900 | - |
dc.contributor.authorscopusid | 6602376272 | - |
dc.contributor.authorscopusid | 57073831000 | - |
dc.contributor.authorscopusid | 6506142524 | - |
dc.identifier.issue | 0146954 | - |
dc.relation.volume | 11 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-TEL | en_US |
dc.description.sjr | 1,201 | |
dc.description.jcr | 2,806 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
dc.description.erihplus | ERIH PLUS | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUMA: Sistemas de Información y Comunicaciones | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Telemática | - |
crisitem.author.dept | GIR IDeTIC: División de Procesado Digital de Señales | - |
crisitem.author.dept | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.dept | GIR IUSA-ONEHEALTH 5: Reproducción Animal, Oncología y Anestesiología Comparadas | - |
crisitem.author.dept | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.author.dept | Departamento de Morfología | - |
crisitem.author.orcid | 0000-0002-0907-4765 | - |
crisitem.author.orcid | 0000-0002-4621-2768 | - |
crisitem.author.orcid | 0000-0003-4953-7653 | - |
crisitem.author.orcid | 0000-0001-9041-153X | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.parentorg | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.author.fullName | Hernández Morera, Pablo Vicente | - |
crisitem.author.fullName | Travieso González, Carlos Manuel | - |
crisitem.author.fullName | Mompeó Corredera,Blanca Rosa | - |
crisitem.author.fullName | Ortega Santana, Francisco Cándido | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
23
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
26
checked on Nov 17, 2024
Page view(s)
106
checked on Jul 27, 2024
Download(s)
115
checked on Jul 27, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.