Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/45332
DC FieldValueLanguage
dc.contributor.authorGonzález-Antuña, Anaen_US
dc.contributor.authorDomínguez-Romero, Juan C.en_US
dc.contributor.authorGarcía-Reyes, Juan F.en_US
dc.contributor.authorRodríguez-González, Pabloen_US
dc.contributor.authorCentineo, Giuseppeen_US
dc.contributor.authorGarcía Alonso, J. Ignacioen_US
dc.contributor.authorMolina-Díaz, Antonioen_US
dc.date.accessioned2018-11-22T09:00:54Z-
dc.date.available2018-11-22T09:00:54Z-
dc.date.issued2013en_US
dc.identifier.issn0021-9673en_US
dc.identifier.urihttp://hdl.handle.net/10553/45332-
dc.description.abstractIn this work, the implementation of isotope dilution mass spectrometry (IDMS) using minimal labeling and isotope pattern deconvolution (IPD) is evaluated as a strategy for the minimization of matrix effects during trace determination of β2-agonists in complex matrices by liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS). First, the parameters affecting the measurement of isotopic composition of organic compounds by liquid chromatography electrospray ionization high resolution mass spectrometry with a time-of-flight analyzer were evaluated using as a case of study three different β2-agonists: clenbuterol, clenproperol and brombuterol. Then, a calibration graph-free IDMS methodology was evaluated in order to overcome matrix effects in LC-ESI-MS in complex samples. In this procedure singly (13)C-labeled analogues of clenbuterol, clenproperol and brombuterol were employed in combination with IPD. Using this approach accurate and precise results were obtained in the simultaneous quantification of β2-agonists in human urine and bovine liver, even at the sub ngg(-1) and particularly in spite of the previously reported matrix effects. Recovery rates in the range of 97-114% in fortified human urine and from 95% to 111% in fortified bovine liver were obtained with RSD (%) of independent recovery experiments always lower than 6%. These results demonstrate that the proposed methodology based on the use of (13)C1-labeled standards and IPD is a reliable approach for accurate LC-MS quantitation of small molecules and compatible with full-scan high-resolution mass spectrometry.en_US
dc.languageengen_US
dc.relation.ispartofJournal of Chromatography Aen_US
dc.sourceJournal of Chromatography A [ISSN 0021-9673],v. 1288, p. 40-47 (Mayo 2013)en_US
dc.subject32 Ciencias médicasen_US
dc.subject230103 Análisis cromatográficoen_US
dc.subject230110 Espectroscopia de masasen_US
dc.subject.otherElectrosprayen_US
dc.subject.otherβ-agonistsen_US
dc.subject.otherChromatography-mass spectrometryen_US
dc.titleOvercoming matrix effects in electrospray: Quantitation of β-agonists in complex matrices by isotope dilution liquid chromatography-mass spectrometry using singly <sup>13</sup>C-labeled analoguesen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.chroma.2013.02.074en_US
dc.identifier.scopus84876077293-
dc.contributor.authorscopusid36058862700-
dc.contributor.authorscopusid53263319000-
dc.contributor.authorscopusid56360245800-
dc.contributor.authorscopusid6603228633-
dc.contributor.authorscopusid35557054000-
dc.contributor.authorscopusid7005508838-
dc.contributor.authorscopusid57190577987-
dc.description.lastpage47en_US
dc.description.firstpage40en_US
dc.relation.volume1288en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.description.numberofpages8en_US
dc.utils.revisionen_US
dc.date.coverdateMayo 2013en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr2,017
dc.description.jcr4,258
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.fullNameGonzález Antuña, Ana-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

50
checked on Mar 30, 2025

WEB OF SCIENCETM
Citations

48
checked on Mar 30, 2025

Page view(s)

59
checked on Oct 31, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.