Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/45331
Title: Simultaneous determination of seven β2-agonists in human and bovine urine by isotope dilution liquid chromatography-tandem mass spectrometry using compound-specific minimally 13C-labelled analogues
Authors: González-Antuña, Ana 
Rodríguez-González, Pablo
Centineo, Giuseppe
García Alonso, J. Ignacio
UNESCO Clasification: 32 Ciencias médicas
230103 Análisis cromatográfico
230110 Espectroscopia de masas
Keywords: Isotope dilution
Liquid chromatography
Matrix effects
Minimal labeling
Selected reaction monitoring, et al
Issue Date: 2014
Journal: Journal of Chromatography A 
Abstract: Seven β2-agonist (clenproperol, clenbuterol, salbutamol, bronbuterol, ractopamine, clenpenterol and clencyclohexerol) were determined simultaneously in human and bovine urine by isotope dilution LC-ESI-MS/MS in a triple quadrupole instrument. The method is based on the application of multiple linear regression in combination with compound-specific minimally 13C-labelled analogues. Additionally, the increase of the bandpass of the first quadrupole during the selected reaction monitoring (SRM) measurement procedure allowed the simultaneous quantification of the seven compounds at sub ngg-1 levels in a single chromatogram without resorting to a methodological calibration graph. Recovery values at concentration levels between 5.0 and 0.05ngg-1 ranged from 95 to 110% in fortified bovine urine and from 91 to 108% in human urine, with relative standard deviations lower than 5% except for salbutamol and ractopamine. The proposed methodology was validated by analyzing the certified reference material BCR-503 (lyophilized bovine urine) certified for clenbuterol and salbutamol. The limits of detection (LOD) for a sample volume of 10mL of both human and bovine urine was found to be lower than 0.012ngg-1 for all compounds, except to salbutamol in bovine urine which was of 0.029ngg-1. The use of compound-specific isotopically labelled analogues minimally labelled in 13C minimized the occurrence of isotope effects and corrected for matrix effects during ESI ionization and can be efficiently applied for the quantification of ultra-trace concentrations of β2-agonists in human and bovine urine.
URI: http://hdl.handle.net/10553/45331
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2014.10.065
Source: Journal of Chromatography A [ISSN 0021-9673], v. 1372, p. 63-71
Appears in Collections:Artículos
Show full item record

SCOPUSTM   
Citations

16
checked on Apr 21, 2024

Page view(s)

30
checked on Oct 15, 2023

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.