Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/43836
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Saavedra, Enrique Ruiz | en_US |
dc.contributor.author | Gotor, Antonio Gómez | en_US |
dc.contributor.author | Pérez Báez, Sebastián O. | en_US |
dc.contributor.author | Ramos, Martín Alejandro | en_US |
dc.contributor.other | Perez Baez, Sebastian O. | - |
dc.contributor.other | Ramos, Alejandro | - |
dc.date.accessioned | 2018-11-21T18:12:22Z | - |
dc.date.available | 2018-11-21T18:12:22Z | - |
dc.date.issued | 2013 | en_US |
dc.identifier.issn | 1944-3994 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/43836 | - |
dc.description.abstract | This paper proposes a simple calculation method to estimate the maximum conversion level in reverse osmosis (RO) brackish water desalination plants. The method is based on the scaling potential of different compounds found in the water to be treated. These compounds include silica, calcium carbonate, calcium sulphate, barium sulphate, strontium sulphate and calcium fluoride. Although the method was originally conceived for application to subterranean brackish waters in the Canary Islands, Spain (principally Gran Canaria, Fuerteventura and Tenerife), it can be extrapolated to other types of region and water treatable with RO systems. The required input data are the chemical composition of the feed water and its pH and temperature. The programmed method then determines the maximum conversion level of the RO system without the risk of scaling of any of the solutes present in the water. The method can be used as an aid in design optimization of RO brackish water desalination plants with acid-free pre-treatment processes and only the use of scale inhibitors. | en_US |
dc.language | eng | en_US |
dc.publisher | 1944-3994 | - |
dc.relation.ispartof | Desalination and Water Treatment | en_US |
dc.source | Desalination and Water Treatment [ISSN 1944-3994], v. 51(4), p. 1143-1150 | en_US |
dc.subject | 330806 Regeneración del agua | en_US |
dc.subject.other | Reverse osmosis | en_US |
dc.subject.other | Desalination plants | en_US |
dc.subject.other | RO system design | en_US |
dc.title | Estimation of the maximum conversion level in reverse osmosis brackish water desalination plants | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.relation.conference | International Conference of the European-Desalination-Society (EDS) on Desalination for the Environment, Clean Water and Energy | |
dc.identifier.doi | 10.1080/19443994.2012.704732 | |
dc.identifier.scopus | 84875785323 | - |
dc.identifier.isi | 000313794400060 | - |
dcterms.isPartOf | Desalination And Water Treatment | - |
dcterms.source | Desalination And Water Treatment[ISSN 1944-3994],v. 51 (4-6), p. 1143-1150 | - |
dc.contributor.authorscopusid | 16198715500 | - |
dc.contributor.authorscopusid | 6603157518 | - |
dc.contributor.authorscopusid | 6506878715 | - |
dc.contributor.authorscopusid | 24341941100 | - |
dc.description.lastpage | 1150 | - |
dc.description.firstpage | 1143 | - |
dc.relation.volume | 51 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000313794400060 | - |
dc.contributor.daisngid | 6664150 | - |
dc.contributor.daisngid | 3105421 | - |
dc.contributor.daisngid | 1240221 | - |
dc.contributor.daisngid | 4574046 | - |
dc.identifier.investigatorRID | P-5191-2015 | - |
dc.identifier.investigatorRID | H-4351-2015 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Saavedra, ER | |
dc.contributor.wosstandard | WOS:Gotor, AG | |
dc.contributor.wosstandard | WOS:Baez, SOP | |
dc.contributor.wosstandard | WOS:Martin, AR | |
dc.date.coverdate | Enero 2013 | |
dc.identifier.conferenceid | events120814 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,409 | |
dc.description.jcr | 0,987 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 23-04-2012 | - |
crisitem.event.eventsenddate | 26-04-2012 | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-3536-8481 | - |
crisitem.author.orcid | 0000-0002-6909-0759 | - |
crisitem.author.orcid | 0000-0001-5759-4469 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Gómez Gotor, Antonio | - |
crisitem.author.fullName | Pérez Báez,Sebastián Ovidio | - |
crisitem.author.fullName | Ramos Martín, Alejandro | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
9
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
7
checked on Nov 17, 2024
Page view(s)
79
checked on Jan 23, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.