Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/43615
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Martin, R. | en_US |
dc.contributor.author | Quintana, J. J. | en_US |
dc.contributor.author | Nuez, Ignacio | en_US |
dc.contributor.author | Ramos, Alejandro | en_US |
dc.date.accessioned | 2018-11-21T16:33:23Z | - |
dc.date.available | 2018-11-21T16:33:23Z | - |
dc.date.issued | 2006 | en_US |
dc.identifier.isbn | 978-0-88986-549-5 | en_US |
dc.identifier.issn | 1025-8973 | en_US |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/43615 | - |
dc.description.abstract | An analysis and simulations results of several linearization methods for the model of the buck converter by means of pulse width modulation are presented in this paper. The use of the pulse width modulation causes, in systems like the buck converter, nonlinear models. The operation of this system is based on the control of the output voltage of a passive filter. Common linearization techniques work fine when the modulation frequency is much larger than the natural frequency of the filter, but fail when that frequency is of the same order of magnitude or smaller than this filter frequency. This paper develops a new linearization technique that allows to obtain a linear solution of the buck converter model, without approximations, that allows a very precise control of the buck converter when small modulation frequencies have to be used. This new method permits the design of the buck converter circuit with very fast output dynamic responses. | en_US |
dc.language | eng | en_US |
dc.publisher | ACTA Press | en_US |
dc.relation.ispartof | Proceedings of the IASTED International Conference on Intelligent Systems and Control | en_US |
dc.source | Proceedings of the IASTED International Conference on Modelling, Identification, and Control, MIC [ISSN 1025-8973], p. 43-48 | en_US |
dc.subject | 3307 Tecnología electrónica | en_US |
dc.subject.other | Computer control of electric circuits | en_US |
dc.subject.other | Linearization techniques | en_US |
dc.subject.other | Pwm control | en_US |
dc.title | Linear models of buck converters by means of pulse width modulation | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | 25th IASTED International Conference on Modelling, Identification, and Control, MIC 2006 | en_US |
dc.identifier.scopus | 56149122493 | - |
dc.identifier.isi | 000236371700008 | - |
dc.contributor.authorscopusid | 23094981500 | - |
dc.contributor.authorscopusid | 24341642700 | - |
dc.contributor.authorscopusid | 23392958400 | - |
dc.contributor.authorscopusid | 24341941100 | - |
dc.description.lastpage | 48 | en_US |
dc.description.firstpage | 43 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.contributor.daisngid | 17686619 | - |
dc.contributor.daisngid | 23547541 | - |
dc.contributor.daisngid | 17047039 | - |
dc.contributor.daisngid | 4574046 | - |
dc.description.notas | Editor: M. H. Hamza | en_US |
dc.identifier.eisbn | 9780889865518 | - |
dc.identifier.eisbn | 0889865515 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Martin, R | - |
dc.contributor.wosstandard | WOS:Quintana, JJ | - |
dc.contributor.wosstandard | WOS:Nuez, I | - |
dc.contributor.wosstandard | WOS:Ramos, A | - |
dc.date.coverdate | Diciembre 2006 | en_US |
dc.identifier.conferenceid | events121356 | - |
dc.identifier.ulpgc | Sí | en_US |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 06-01-2006 | - |
crisitem.event.eventsenddate | 08-01-2006 | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IDeTIC: División de Procesado Digital de Señales | - |
crisitem.author.dept | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IUNAT: Control analítico de fuentes medioambientales | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-1166-6257 | - |
crisitem.author.orcid | 0000-0001-6652-2360 | - |
crisitem.author.orcid | 0000-0001-5759-4469 | - |
crisitem.author.parentorg | IU para el Desarrollo Tecnológico y la Innovación | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Martín Hernández, Rodolfo | - |
crisitem.author.fullName | Quintana Hernández, José Juan | - |
crisitem.author.fullName | De La Nuez Pestana, Ignacio Agustín | - |
crisitem.author.fullName | Ramos Martín, Alejandro | - |
Appears in Collections: | Actas de congresos |
WEB OF SCIENCETM
Citations
1
checked on Feb 25, 2024
Page view(s)
69
checked on Jun 29, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.