Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/42889
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Martel, O. | en_US |
dc.contributor.author | Carta, J. A. | en_US |
dc.contributor.author | Garcés, Gerardo L. | en_US |
dc.date.accessioned | 2018-11-21T11:33:15Z | - |
dc.date.available | 2018-11-21T11:33:15Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.issn | 1350-4533 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/42889 | - |
dc.description.abstract | In this paper the design and experimental analysis is presented of a new fixation device of anterior cruciate ligament (ACL) grafts of the knee. This device is inserted into the bone tunnel, after the graft, in the same way as an interference screw. However, the fixation device described in this paper has been designed in such a way that, after the insertion of a threaded element in its interior, some of its components expand in a radial direction, pressing against the walls of the bone tunnel and thereby increasing the fixation of the graft. This expansion device can be used in both the femur and the tibia. The device proposed in this paper was compared with an interference screw for load failure and fixation stiffness in experiments performed using porcine bones. The failure load was significantly higher in the new expansion device group (633 ± 202 N) than in the interference screw group (471 ± 179 N). The stiffness obtained when the new device was used (59 ± 20 N/mm) was also significantly higher than that obtained using the interference screw (37 ± 19 N/mm) (t-test, P < 0.05). According to these results, this new device could be considered a good alternative to improve fixation of anterior cruciate ligament grafts. | en_US |
dc.language | eng | en_US |
dc.publisher | 1350-4533 | - |
dc.relation.ispartof | Medical Engineering and Physics | en_US |
dc.source | Medical Engineering and Physics [ISSN 1350-4533], v. 29, p. 163-168 | en_US |
dc.subject | 320714 Osteopatología | en_US |
dc.subject | 331402 Prótesis | en_US |
dc.subject.other | Anterior cruciate ligament reconstruction | en_US |
dc.subject.other | Interference screw | en_US |
dc.subject.other | Implant design Mechanical testing | en_US |
dc.subject.other | Mechanical testing | en_US |
dc.title | A new device for the fixation of anterior cruciate ligament tendon grafts. Design and experimental study | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.medengphy.2006.01.013 | en_US |
dc.identifier.scopus | 33750430647 | - |
dc.identifier.isi | 000243681400021 | - |
dc.contributor.authorscopusid | 15048342800 | - |
dc.contributor.authorscopusid | 7003652043 | - |
dc.contributor.authorscopusid | 56406565300 | - |
dc.description.lastpage | 168 | en_US |
dc.description.firstpage | 163 | en_US |
dc.relation.volume | 29 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 12629772 | - |
dc.contributor.daisngid | 1198474 | - |
dc.contributor.daisngid | 34942581 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Martel, O | - |
dc.contributor.wosstandard | WOS:Carta, JA | - |
dc.contributor.wosstandard | WOS:Garces, G | - |
dc.date.coverdate | Enero 2007 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.jcr | 1,471 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0003-3806-5523 | - |
crisitem.author.orcid | 0000-0003-1379-0075 | - |
crisitem.author.orcid | 0000-0003-4494-9077 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Martel Fuentes, Oscar | - |
crisitem.author.fullName | Carta González, José Antonio | - |
crisitem.author.fullName | Garcés Martín, Gerardo | - |
Colección: | Artículos |
Citas SCOPUSTM
7
actualizado el 10-nov-2024
Citas de WEB OF SCIENCETM
Citations
7
actualizado el 10-nov-2024
Visitas
62
actualizado el 10-feb-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.