Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/42673
Campo DC Valoridioma
dc.contributor.authorMartel, Oscaren_US
dc.contributor.authorCárdenes, Juan F.en_US
dc.contributor.authorGarcés, Gerardo L.en_US
dc.contributor.authorCarta, José A.en_US
dc.date.accessioned2018-11-21T10:37:04Z-
dc.date.available2018-11-21T10:37:04Z-
dc.date.issued2009en_US
dc.identifier.issn1065-8483en_US
dc.identifier.urihttp://hdl.handle.net/10553/42673-
dc.description.abstractAnterior cruciate ligament (ACL) reconstruction is one of the most important aspects of knee surgery. For this purpose, several fixation devices have been developed, although the interference screw is the most frequently used. The most typical biomechanical test of these devices consists of placing them in a testing machine and subjecting them to a pull-out test. However, insufficient attention has been paid to the influence of the displacement test rate on the mechanical properties of the fixation system. The aim of this study is to compare the influence of the crosshead rate in the biomechanical test of two different devices for the fixation of ACL tendon grafts. One hundred in vitro tests were performed using porcine tibiae and bovine tendons. The fixation devices used were (1) an interference screw and (2) a new expansion device. All ACL reconstructions were subjected to pull-out test to failure. Five crosshead rates were employed in a range from 30 mm/min to 4000 mm/min. Statistical analyses of the results show that, for the two devices, the rate has a significant effect on both maximum force and stiffness. Moreover, the new expansion device showed lesser dependency on the crosshead rate than the interference screw.en_US
dc.languageengen_US
dc.publisher1065-8483-
dc.relationValidacion y Rediseño de Mecanismos de Expansion Radial Para la Fijacion Osea de Injertos Del Ligamento Cruzado Anterior de la Rodillaen_US
dc.relation.ispartofJournal of Applied Biomechanicsen_US
dc.sourceJournal of Applied Biomechanics[ISSN 1065-8483],v. 25, p. 313-321en_US
dc.subject320714 Osteopatologíaen_US
dc.subject331402 Prótesisen_US
dc.subject.otherAnterior cruciate ligamenten_US
dc.subject.otherIn vitro testen_US
dc.subject.otherClinical biomechanicsen_US
dc.titleInfluence of the crosshead rate on the mechanical properties of fixation systems of ACL tendon graftsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1123/jab.25.4.313en_US
dc.identifier.scopus70350721787-
dc.identifier.isi000271776700004-
dc.contributor.authorscopusid15048342800-
dc.contributor.authorscopusid13806036200-
dc.contributor.authorscopusid56406565300-
dc.contributor.authorscopusid7003652043-
dc.description.lastpage321en_US
dc.description.firstpage313en_US
dc.relation.volume25en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid12629772-
dc.contributor.daisngid11297995-
dc.contributor.daisngid34942581-
dc.contributor.daisngid1198474-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Martel, O-
dc.contributor.wosstandardWOS:Cardenes, JF-
dc.contributor.wosstandardWOS:Garces, G-
dc.contributor.wosstandardWOS:Carta, JA-
dc.date.coverdateEnero 2009en_US
dc.identifier.ulpgcen_US
dc.description.jcr0,81-
dc.description.jcrqQ3-
dc.description.scieSCIE-
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.project.principalinvestigatorCarta González, José Antonio-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.deptGIR Group for the Research on Renewable Energy Systems-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0003-3806-5523-
crisitem.author.orcid0000-0003-4494-9077-
crisitem.author.orcid0000-0003-1379-0075-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameMartel Fuentes, Oscar-
crisitem.author.fullNameCárdenes Martín, Juan Francisco-
crisitem.author.fullNameGarcés Martín, Gerardo-
crisitem.author.fullNameCarta González, José Antonio-
Colección:Artículos
Adobe PDF (372,05 kB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.