Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/42673
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Martel, Oscar | en_US |
dc.contributor.author | Cárdenes, Juan F. | en_US |
dc.contributor.author | Garcés, Gerardo L. | en_US |
dc.contributor.author | Carta, José A. | en_US |
dc.date.accessioned | 2018-11-21T10:37:04Z | - |
dc.date.available | 2018-11-21T10:37:04Z | - |
dc.date.issued | 2009 | en_US |
dc.identifier.issn | 1065-8483 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/42673 | - |
dc.description.abstract | Anterior cruciate ligament (ACL) reconstruction is one of the most important aspects of knee surgery. For this purpose, several fixation devices have been developed, although the interference screw is the most frequently used. The most typical biomechanical test of these devices consists of placing them in a testing machine and subjecting them to a pull-out test. However, insufficient attention has been paid to the influence of the displacement test rate on the mechanical properties of the fixation system. The aim of this study is to compare the influence of the crosshead rate in the biomechanical test of two different devices for the fixation of ACL tendon grafts. One hundred in vitro tests were performed using porcine tibiae and bovine tendons. The fixation devices used were (1) an interference screw and (2) a new expansion device. All ACL reconstructions were subjected to pull-out test to failure. Five crosshead rates were employed in a range from 30 mm/min to 4000 mm/min. Statistical analyses of the results show that, for the two devices, the rate has a significant effect on both maximum force and stiffness. Moreover, the new expansion device showed lesser dependency on the crosshead rate than the interference screw. | en_US |
dc.language | eng | en_US |
dc.publisher | 1065-8483 | - |
dc.relation | Validacion y Rediseño de Mecanismos de Expansion Radial Para la Fijacion Osea de Injertos Del Ligamento Cruzado Anterior de la Rodilla | en_US |
dc.relation.ispartof | Journal of Applied Biomechanics | en_US |
dc.source | Journal of Applied Biomechanics[ISSN 1065-8483],v. 25, p. 313-321 | en_US |
dc.subject | 320714 Osteopatología | en_US |
dc.subject | 331402 Prótesis | en_US |
dc.subject.other | Anterior cruciate ligament | en_US |
dc.subject.other | In vitro test | en_US |
dc.subject.other | Clinical biomechanics | en_US |
dc.title | Influence of the crosshead rate on the mechanical properties of fixation systems of ACL tendon grafts | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1123/jab.25.4.313 | en_US |
dc.identifier.scopus | 70350721787 | - |
dc.identifier.isi | 000271776700004 | - |
dc.contributor.authorscopusid | 15048342800 | - |
dc.contributor.authorscopusid | 13806036200 | - |
dc.contributor.authorscopusid | 56406565300 | - |
dc.contributor.authorscopusid | 7003652043 | - |
dc.description.lastpage | 321 | en_US |
dc.description.firstpage | 313 | en_US |
dc.relation.volume | 25 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 12629772 | - |
dc.contributor.daisngid | 11297995 | - |
dc.contributor.daisngid | 34942581 | - |
dc.contributor.daisngid | 1198474 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Martel, O | - |
dc.contributor.wosstandard | WOS:Cardenes, JF | - |
dc.contributor.wosstandard | WOS:Garces, G | - |
dc.contributor.wosstandard | WOS:Carta, JA | - |
dc.date.coverdate | Enero 2009 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.description.jcr | 0,81 | - |
dc.description.jcrq | Q3 | - |
dc.description.scie | SCIE | - |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.project.principalinvestigator | Carta González, José Antonio | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0003-3806-5523 | - |
crisitem.author.orcid | 0000-0003-4494-9077 | - |
crisitem.author.orcid | 0000-0003-1379-0075 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Martel Fuentes, Oscar | - |
crisitem.author.fullName | Cárdenes Martín, Juan Francisco | - |
crisitem.author.fullName | Garcés Martín, Gerardo | - |
crisitem.author.fullName | Carta González, José Antonio | - |
Colección: | Artículos |
Citas SCOPUSTM
2
actualizado el 15-dic-2024
Citas de WEB OF SCIENCETM
Citations
2
actualizado el 15-dic-2024
Visitas
109
actualizado el 07-sep-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.