Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/42514
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Feo García, José Juan | en_US |
dc.contributor.author | Ruiz García, Alejandro | en_US |
dc.contributor.author | Ruiz Saavedra, E. | en_US |
dc.contributor.author | Melian-Martel, N. | en_US |
dc.contributor.other | Ruiz Garcia, Alejandro | - |
dc.date.accessioned | 2018-11-19T16:42:34Z | - |
dc.date.available | 2018-11-19T16:42:34Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 1944-3994 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/42514 | - |
dc.description.abstract | Water resources available in the island of Fuerteventura come mostly from small-scale capacity seawater desalination plants. Desalted water demand in the island has grown considerably in the last decade forcing managers to adapt desalinated water supply constantly. Additionally, the operating cost of the plants is relevant. The staff, chemical consumption, cartridge filter, and membrane replacement cost are essential in order to establish more efficient operation conditions of a reverse osmosis desalination plant. This article aims to study and compare the mentioned cost of six different seawater reverse osmosis desalination plants with the same production of 600Â m3/d in the island of Fuerteventura. The results show for each of the six cases how costs can be reduced and the essential role of automation dealing with the staff cost with the particular capacity of 600Â m3/d. | - |
dc.language | eng | en_US |
dc.relation.ispartof | Desalination and Water Treatment | en_US |
dc.source | Desalination and Water Treatment [ISSN 1944-3994], v. 57 (48-49), p. 22887-22893 | en_US |
dc.subject | 330806 Regeneración del agua | - |
dc.subject | 3306 Ingeniería y tecnología eléctricas | - |
dc.subject.other | Desalination plants | - |
dc.subject.other | Normalization | - |
dc.subject.other | Operating data | - |
dc.subject.other | Reverse osmosis | - |
dc.subject.other | Seawater | - |
dc.title | Cost assessment in SWRO desalination plants with a production of 600 m3/d in Canary Islands | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.relation.conference | European-Desalination-Society (EuroMed) Conference on Desalination for Clean Water and Energy | |
dc.identifier.doi | 10.1080/19443994.2015.1133873 | |
dc.identifier.scopus | 2-s2.0-84953721185 | - |
dc.identifier.isi | 000384641000021 | - |
dcterms.isPartOf | Desalination And Water Treatment | - |
dcterms.source | Desalination And Water Treatment[ISSN 1944-3994],v. 57 (48-49), p. 22887-22893 | - |
dc.contributor.authorscopusid | 56925498900 | - |
dc.contributor.authorscopusid | 55749145800 | - |
dc.contributor.authorscopusid | 56092031900 | - |
dc.contributor.authorscopusid | 46461751500 | - |
dc.description.lastpage | 22893 | - |
dc.identifier.issue | 48-49 | - |
dc.description.firstpage | 22887 | - |
dc.relation.volume | 57 | - |
dc.investigacion | Ingeniería y Arquitectura | - |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000384641000021 | - |
dc.contributor.daisngid | 5705574 | - |
dc.contributor.daisngid | 2368242 | - |
dc.contributor.daisngid | 5510440 | - |
dc.contributor.daisngid | 4015544 | - |
dc.identifier.investigatorRID | M-3697-2014 | - |
dc.contributor.wosstandard | WOS:Feo-Garcia, J | |
dc.contributor.wosstandard | WOS:Ruiz-Garcia, A | |
dc.contributor.wosstandard | WOS:Ruiz-Saavedra, E | |
dc.contributor.wosstandard | WOS:Melian-Martel, N | |
dc.date.coverdate | 2016 | |
dc.identifier.conferenceid | events120995 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,343 | |
dc.description.jcr | 1,631 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0001-5286-9005 | - |
crisitem.author.orcid | 0000-0002-5209-653X | - |
crisitem.author.orcid | 0000-0001-5271-1443 | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Feo García, José Juan | - |
crisitem.author.fullName | Ruiz García, Alejandro | - |
crisitem.author.fullName | Melián Martel, Noemí | - |
crisitem.event.eventsstartdate | 10-05-2015 | - |
crisitem.event.eventsenddate | 14-05-2015 | - |
Colección: | Artículos |
Citas SCOPUSTM
8
actualizado el 03-nov-2024
Citas de WEB OF SCIENCETM
Citations
6
actualizado el 03-nov-2024
Visitas
129
actualizado el 04-may-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.