Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/42419
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Feo García, José Juan | en_US |
dc.contributor.author | Ruiz García, Alejandro | en_US |
dc.contributor.author | Ruiz-Saavedra, E. | en_US |
dc.contributor.author | Melián-Martel, Noemí | en_US |
dc.contributor.other | Ruiz Garcia, Alejandro | - |
dc.date.accessioned | 2018-11-12T20:06:06Z | - |
dc.date.available | 2018-11-12T20:06:06Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 1944-3994 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/42419 | - |
dc.description.abstract | The Canary Islands has been pioneer on desalination in Europe since the 1960s and has continued to use intensively the desalination technologies in order to provide water resources. However, one of the most important problems related to the operating efficient of seawater reverse osmosis (SWRO) desalination plants is dealing with the high-energy consumption. The present article aims to study, define, and compare the energy consumption cost of five SWRO desalination plants with the same production of 4,000 m3/d in the island of Fuerteventura (Canary Islands). The methodology for carrying out the work is based on analyzing the energy consumption data that directly affect to the operating cost. A comparison between different energy recovery systems was carried out using the data collected over 5 years of operation. The article presents an assessment of different ways to get more efficient operating conditions in order to reduce the operating cost. | - |
dc.language | eng | en_US |
dc.relation.ispartof | Desalination and Water Treatment | en_US |
dc.source | Desalination and Water Treatment [ISSN 1944-3994], v. 57 (48-49), p. 23019-23023 | en_US |
dc.subject | 330806 Regeneración del agua | - |
dc.subject | 330810 Tecnología de aguas residuales | - |
dc.subject | 330811 Control de la contaminación del agua | - |
dc.subject.other | Desalination plants | - |
dc.subject.other | Normalization | - |
dc.subject.other | Operating data | - |
dc.subject.other | Reverse osmosis | - |
dc.subject.other | Seawater | - |
dc.title | Energy consumption assessment of 4,000 m3/d SWRO desalination plants | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.relation.conference | European-Desalination-Society (EuroMed) Conference on Desalination for Clean Water and Energy | |
dc.identifier.doi | 10.1080/19443994.2015.1106095 | |
dc.identifier.scopus | 2-s2.0-84945275035 | - |
dc.identifier.isi | 000384641000035 | - |
dcterms.isPartOf | Desalination And Water Treatment | - |
dcterms.source | Desalination And Water Treatment[ISSN 1944-3994],v. 57 (48-49), p. 23019-23023 | - |
dc.contributor.authorscopusid | 56925498900 | - |
dc.contributor.authorscopusid | 55749145800 | - |
dc.contributor.authorscopusid | 56092031900 | - |
dc.contributor.authorscopusid | 46461751500 | - |
dc.description.lastpage | 23023 | - |
dc.identifier.issue | 48-49 | - |
dc.description.firstpage | 23019 | - |
dc.relation.volume | 57 | - |
dc.investigacion | Ingeniería y Arquitectura | - |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000384641000035 | - |
dc.contributor.daisngid | 5705574 | - |
dc.contributor.daisngid | 2368242 | - |
dc.contributor.daisngid | 5510440 | - |
dc.contributor.daisngid | 4015544 | - |
dc.identifier.investigatorRID | M-3697-2014 | - |
dc.contributor.wosstandard | WOS:Feo-Garcia, J | |
dc.contributor.wosstandard | WOS:Ruiz-Garcia, A | |
dc.contributor.wosstandard | WOS:Ruiz-Saavedra, E | |
dc.contributor.wosstandard | WOS:Melian-Martel, N | |
dc.date.coverdate | 2016 | |
dc.identifier.conferenceid | events120995 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,343 | |
dc.description.jcr | 1,631 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.event.eventsstartdate | 10-05-2015 | - |
crisitem.event.eventsenddate | 14-05-2015 | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR Energía, Corrosión, Residuos y Agua | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0001-5286-9005 | - |
crisitem.author.orcid | 0000-0002-5209-653X | - |
crisitem.author.orcid | 0000-0001-5271-1443 | - |
crisitem.author.orcid | 0000-0001-5271-1443 | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Feo García, José Juan | - |
crisitem.author.fullName | Ruiz García, Alejandro | - |
crisitem.author.fullName | Melián Martel, Noemí | - |
crisitem.author.fullName | Melián Martel, Noemí | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
3
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
3
checked on Nov 17, 2024
Page view(s)
118
checked on Apr 13, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.