Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/41847
Título: | Fouling characterization of RO membranes after 11 years of operation in a brackish water desalination plant | Autores/as: | Ruiz-García, A. Melián-Martel, N. Mena, V. |
Clasificación UNESCO: | 3308 Ingeniería y tecnología del medio ambiente 330806 Regeneración del agua |
Palabras clave: | Brackish water Reverse osmosis Fouling Scaling Membrane autopsy |
Fecha de publicación: | 2018 | Publicación seriada: | Desalination (Amsterdam) | Resumen: | Fouled BWRO membrane elements from a full-scale desalination plant were characterized by collecting performance data and through a membrane autopsy in order to identify the fouling characteristics and behavior associated with feed water inorganic composition and operating conditions. This is the first time that membranes of a desalination plant have been autopsied with a data collection along 11 years of operation. The investigated membrane elements were taken after 11 years of operation. The BWRO desalination plant had a production capacity of 15 m(3) d(-1) with a recovery of 60% approximately. It was fed from a groundwater well having cartridge filters and antiscalant dosing as a pre-treatment. It is a two stages desalination plant with the BW30-400 membrane element. Chemical and structural characterization was performed by visual inspection, qualitative analysis test and by scanning electron microscopy with energy dispersive X-ray (SEM-EDX). The fouling layer consisted of a biofilm detected in the first elements of the RO system. Biofilm comprising diatoms on all membrane elements were found. Inorganic foulants mainly consisted of calcium carbonate and aluminosilicates. The results highlight that it is possible to preserve BWRO membrane elements in service for up to 11 years using a correct conventional pretreatment with this kind of foulants. However, the membrane resistant increased more than twice over the operating period. | URI: | http://hdl.handle.net/10553/41847 | ISSN: | 0011-9164 | DOI: | 10.1016/j.desal.2017.12.046 | Fuente: | Desalination[ISSN 0011-9164],v. 430, p. 180-185 |
Colección: | Artículos |
Citas SCOPUSTM
49
actualizado el 01-dic-2024
Citas de WEB OF SCIENCETM
Citations
45
actualizado el 24-nov-2024
Visitas
130
actualizado el 28-sep-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.