Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/41807
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guerra Hernández, E. | en_US |
dc.contributor.author | Rodríguez Pérez, Aurelio | en_US |
dc.contributor.author | Freixinet Gilard, J. | en_US |
dc.contributor.author | Martín Álamo, M. N. | en_US |
dc.contributor.author | Escudero Socorro, M. | en_US |
dc.contributor.author | Rodríguez Suárez, P. | en_US |
dc.contributor.author | Esquinas, A. M. | en_US |
dc.date.accessioned | 2018-09-03T09:43:52Z | - |
dc.date.available | 2018-09-03T09:43:52Z | - |
dc.date.issued | 2018 | en_US |
dc.identifier.issn | 1128-3602 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/41807 | - |
dc.description.abstract | OBJECTIVE: To evaluate if the prophylactic application of BiPAP previous to lung resection and 17 hours postoperatively improves respiratory function. In order to do this, we studied the results of arterial blood gases and portable spirometry in the immediate postoperative period and at the first and third postoperative day. Secondary objectives included evaluating whether this same pattern decreases the incidence of postoperative pulmonary complications (PPC) and hospital stay. PATIENTS AND METHODS: This was a prospective, randomized clinical study. Between January 2012 and June 2013, 50 patients who had undergone lung resection with posterolateral thoracotomy were assigned to one of two groups by a random number generator according to whether or not they would receive prophylactic BiPAP pre- and postoperatively. RESULTS: The results of the gasometric and spirometric values were similar in both groups. There were no statistically significant differences (p > 0.05). There was not a decrease in the incidence of PPC in the group that received prophylactic BiPAP. Likewise, postoperative stay was similar in both groups. The BiPAP group was 6.60 ± 4 days and the non BiPAP group was 6.84 ± 3.94 days (p = 0.63). CONCLUSIONS: One drawback of this work was the limited number of hours that BiPAP was employed, and when compared to other studies, the application of low-pressure support. We did not find any significant differences between using prophylactic BiPAP or not, suggesting that such treatment should not be performed indiscriminately. More investigations are needed with a larger number of patients in order to better evaluate the possible benefits of using prophylactic BiPAP in thoracic surgery. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | European Review for Medical and Pharmacological Sciences | en_US |
dc.source | European Review for Medical and Pharmacological Sciences [ISSN 1128-3602], v. 22 (1), p. 190-198, (Enero 2018) | en_US |
dc.subject | 321303 Anestesiología | en_US |
dc.subject | 320508 Enfermedades pulmonares | en_US |
dc.subject.other | Noninvasive ventilation | en_US |
dc.subject.other | BiPAP | en_US |
dc.subject.other | Thoracic surgery | en_US |
dc.subject.other | Gas exchange | en_US |
dc.subject.other | Prophylactic noninvasive ventilation | en_US |
dc.title | Prophylactic use of non-invasive mechanical ventilation in lung resection | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.26355/eurrev-201801-14117 | en_US |
dc.identifier.scopus | 85040767261 | - |
dc.identifier.isi | 000423992600025 | - |
dc.contributor.authorscopusid | 57197255108 | - |
dc.contributor.authorscopusid | 7006262225 | - |
dc.contributor.authorscopusid | 57200317726 | - |
dc.contributor.authorscopusid | 57200319355 | - |
dc.contributor.authorscopusid | 57200313335 | - |
dc.contributor.authorscopusid | 8589373900 | - |
dc.contributor.authorscopusid | 6506411821 | - |
dc.description.lastpage | 198 | en_US |
dc.identifier.issue | 1 | - |
dc.description.firstpage | 190 | en_US |
dc.relation.volume | 22 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
local.message.claim | 2020-09-17T12:15:22.097+0100|||rp01018|||submit_approve|||dc_contributor_author|||None | * |
dc.contributor.daisngid | 7071837 | - |
dc.contributor.daisngid | 11389025 | - |
dc.contributor.daisngid | 25393475 | - |
dc.contributor.daisngid | 26876697 | - |
dc.contributor.daisngid | 26695152 | - |
dc.contributor.daisngid | 2524524 | - |
dc.contributor.daisngid | 59249 | - |
dc.contributor.wosstandard | WOS:Hernandez, EG | - |
dc.contributor.wosstandard | WOS:Perez, AR | - |
dc.contributor.wosstandard | WOS:Gilard, JF | - |
dc.contributor.wosstandard | WOS:Alamo, MNM | - |
dc.contributor.wosstandard | WOS:Socorro, ME | - |
dc.contributor.wosstandard | WOS:Suarez, PR | - |
dc.contributor.wosstandard | WOS:Esquinas, AM | - |
dc.date.coverdate | Enero 2018 | en_US |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 0,618 | |
dc.description.jcr | 2,721 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUSA-ONEHEALTH 5: Reproducción Animal, Oncología y Anestesiología Comparadas | - |
crisitem.author.dept | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0003-0947-263X | - |
crisitem.author.orcid | 0000-0002-8158-7872 | - |
crisitem.author.parentorg | IU de Sanidad Animal y Seguridad Alimentaria | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Rodríguez Pérez, Aurelio Eduardo | - |
crisitem.author.fullName | Rodríguez Suárez, Pedro Miguel | - |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
5
checked on Nov 17, 2024
WEB OF SCIENCETM
Citations
2
checked on Feb 25, 2024
Page view(s)
116
checked on Aug 3, 2024
Download(s)
54
checked on Aug 3, 2024
Google ScholarTM
Check
Altmetric
Share
Export metadata