Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/35330
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Socorro, Fabiola | en_US |
dc.contributor.author | Rodríguez de Rivera, Pedro Jesús | en_US |
dc.contributor.author | Rodríguez de Rivera, Miriam | en_US |
dc.contributor.author | de Rivera, Manuel Rodríguez | en_US |
dc.date.accessioned | 2018-04-06T10:31:14Z | - |
dc.date.available | 2018-04-06T10:31:14Z | - |
dc.date.issued | 2017 | en_US |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/35330 | - |
dc.description.abstract | The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body’s local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W(t) = A0 + åAiexp(t/ti). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm2) varies depending on the sensor’s thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 C, this power can vary between 100–250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Sensors | en_US |
dc.source | Sensors (Switzerland)[ISSN 1424-8220],v. 17 (2749) | en_US |
dc.subject | 22 Física | en_US |
dc.subject | 221302 Física de la transmisión del calor | en_US |
dc.subject.other | Direct calorimetry | en_US |
dc.subject.other | Heat conduction calorimeters | en_US |
dc.subject.other | Isothermal calorimeters | en_US |
dc.subject.other | Medical calorimetry | en_US |
dc.subject.other | Non-differential calorimeters | en_US |
dc.title | Mathematical model for localised and surface heat flux of the human body obtained from measurements performed with a calorimetry minisensor | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/s17122749 | en_US |
dc.identifier.scopus | 85047291396 | - |
dc.identifier.isi | 000423285800049 | - |
dc.contributor.authorscopusid | 6603271349 | - |
dc.contributor.authorscopusid | 57202461878 | - |
dc.contributor.authorscopusid | 57202465692 | - |
dc.contributor.authorscopusid | 6506079738 | - |
dc.identifier.issue | 12 | - |
dc.relation.volume | 17 | en_US |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 1486637 | - |
dc.contributor.daisngid | 12460951 | - |
dc.contributor.daisngid | 2312735 | - |
dc.contributor.daisngid | 9287889 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Socorro, F | - |
dc.contributor.wosstandard | WOS:de Rivera, PJR | - |
dc.contributor.wosstandard | WOS:de Rivera, MR | - |
dc.contributor.wosstandard | WOS:de Rivera, MR | - |
dc.date.coverdate | Diciembre 2017 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-BAS | en_US |
dc.description.sjr | 0,584 | |
dc.description.jcr | 2,475 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q2 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.dept | GIR Termofísica de Líquidos y Calorimetría | - |
crisitem.author.dept | Departamento de Física | - |
crisitem.author.orcid | 0000-0002-4890-5947 | - |
crisitem.author.orcid | 0000-0002-6737-4096 | - |
crisitem.author.orcid | 0000-0002-6737-4096 | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.parentorg | Departamento de Física | - |
crisitem.author.fullName | Socorro Lorenzo, Fabiola Lourdes | - |
crisitem.author.fullName | Rodríguez De Rivera Rodríguez, Manuel Jose M. | - |
crisitem.author.fullName | Rodríguez De Rivera Rodríguez, Manuel Jose M. | - |
Colección: | Artículos |
Citas SCOPUSTM
8
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
8
actualizado el 17-nov-2024
Visitas
120
actualizado el 17-feb-2024
Descargas
155
actualizado el 17-feb-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.