dc.description.abstractBACKGROUND Signs of hypovolaemia are frequent in the postoperative period, but not all patients need or respond to fluid administration. An increase in cardiac output (CO) after passive leg raising (PLR) has been demonstrated to be useful as a volume response predictor in non-surgical, spontaneously breathing patients. OBJECTIVE The objective of this study was to evaluate the accuracy of transthoracic echocardiography after PLR to predict fluid responsiveness in post-surgical patients. DESIGN A prospective observational study. SETTING A tertiary hospital between January and July 2015. PATIENTS Fifty-one spontaneously breathing postoperative patients with suspected hypovolaemia (arterial hypotension, oliguria, tachycardia or delayed capillary refill) were considered for the study. INTERVENTION Demographic and personal data were collected, as well as heart rate variations, mean arterial pressure during PLR and after administering 500 ml of Ringer's lactate solution. CO was measured by transthoracic echocardiography. MAIN OUTCOME MEASURES The primary outcome was measurement of CO before and after PLR and Ringer's lactate administration. RESULTS Forty-one patients were included in the study (six patients were excluded because of a poor echocardiographic window and four because of misalignment of the Doppler and outflow tract of the left ventricle). Twenty-two patients (54%) were considered responders to fluid therapy, with an increase of stroke volume greater than or equal to 15% after 500 ml lactated Ringer's infusion. The highest area under the curve was found for an increase in CO (0.91 ± 0.05; 95% confidence interval 0.78 to 0.97). An increase in CO greater than 11% after the PLR manoeuvre predicts a volume response with 68% sensitivity and 100% specificity. CONCLUSION This is the first study showing that measurement of CO after PLR can predict volume response in spontaneously breathing postoperative patients.en_US
dc.languageengen_US
dc.relation.ispartofEuropean Journal of Anaesthesiologyen_US
dc.sourceEuropean Journal of Anaesthesiology [ISSN 0265-0215], v. 34 (11), p. 748-754 (Noviembre 2017)en_US
dc.subject3213 Cirugíaen_US
dc.subject3207 Patologíaen_US
dc.subject320501 Cardiologíaen_US
dc.subject.otherCritically-Ill Patientsen_US
dc.subject.otherPredicting Fluid Responsivenessen_US
dc.subject.otherVentilated Patientsen_US
dc.subject.otherCardiac-Outputen_US
dc.subject.otherVolumeen_US
dc.subject.otherTherapyen_US
dc.titleEchocardiography and passive leg raising in the postoperative period: A prospective observational studyen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1097/EJA.0000000000000679en_US
dc.identifier.pmid34-
dc.identifier.scopus85030697179-
dc.identifier.isi000412411200007-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.authorscopusid57195987849-
dc.contributor.authorscopusid26638522700-
dc.contributor.authorscopusid57195983654-
dc.contributor.authorscopusid7006262225-
dc.contributor.authorscopusid7403122266-
dc.identifier.eissn1365-2346-
dc.description.lastpage754en_US
dc.identifier.issue11-
dc.description.firstpage748en_US
dc.relation.volume34en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
local.message.claim2020-09-17T12:17:02.363+0100|||rp01018|||submit_approve|||dc_contributor_author|||None-
dc.contributor.daisngid21628415-
dc.contributor.daisngid8719356-
dc.contributor.daisngid18663952-
dc.contributor.daisngid6363126-
dc.contributor.daisngid168-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:El Hadouti, Y-
dc.contributor.wosstandardWOS:Valencia, L-
dc.contributor.wosstandardWOS:Becerra, A-
dc.contributor.wosstandardWOS:Rodriguez-Perez, A-
dc.contributor.wosstandardWOS:Vincent, JL-
dc.date.coverdateNoviembre 2017en_US
dc.identifier.ulpgces
dc.description.sjr1,179
dc.description.jcr3,979
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.deptGIR IUSA-ONEHEALTH 5: Reproducción Animal, Oncología y Anestesiología Comparadas-
crisitem.author.deptIU de Sanidad Animal y Seguridad Alimentaria-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.orcid0000-0002-2817-3144-
crisitem.author.orcid0000-0003-0947-263X-
crisitem.author.parentorgIU de Sanidad Animal y Seguridad Alimentaria-
crisitem.author.fullNameBecerra Bolaños, Ángel-
crisitem.author.fullNameRodríguez Pérez, Aurelio Eduardo-
Colección:Artículos
pdf
Unknown (222,59 kB)
Vista resumida

Citas SCOPUSTM   

13
actualizado el 10-nov-2024

Citas de WEB OF SCIENCETM
Citations

12
actualizado el 10-nov-2024

Visitas

106
actualizado el 19-oct-2024

Descargas

225
actualizado el 19-oct-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.