Please use this identifier to cite or link to this item: https://accedacris.ulpgc.es/jspui/handle/10553/158482
DC FieldValueLanguage
dc.contributor.authorBertapelle, Matteoen_US
dc.contributor.authorMirza Rosca, Julia Claudiaen_US
dc.contributor.authorBorges, Joelen_US
dc.contributor.authorViela Vaz, José Filipeen_US
dc.date.accessioned2026-02-19T16:11:26Z-
dc.date.available2026-02-19T16:11:26Z-
dc.date.issued2025en_US
dc.identifier.isbn978-625-7960-84-7en_US
dc.identifier.urihttps://accedacris.ulpgc.es/jspui/handle/10553/158482-
dc.description.abstractThe present study focuses on the differences in behaviour and corrosion properties between three titanium thin films produced with different growth geometries. Two of the thin films were prepared with the same angle of deposition (60º), but different growth geometries (inclined and zig-zag), while the third (the reference sample) was prepared by the conventional geometry (normal incidence, 0º). Multiple analysis was conducted on these samples to reach a better understand the influence of the growth geometry on the corrosion response of the films. Characterization support analysis carried by scanning electron Microscopy (SEM) was used to investigate parameters such as thickness and morphological features, while atomic force microscopy (AFM) was used for surface roughness characterization. X-ray diffraction (XRD) was used to characterize the crystallinity state of the thin films. Regarding corrosion tests in simulated physiological fluid, a mix of alternating and continuous current techniques was used. The obtained results showed that varying the deposition geometry, a significant change on the material corrosion resistance is observed. The results show that there is an improvement in corrosion resistance in both the zigzag and inclined prepared samples, when compared to the conventional geometry grown sample. The sample prepared in the zigzag geometry reveals the highest corrosion resistance in simulated body fluid. These findings reinforce the conclusion that complex surface architectures enable the design of surfaces with distinct properties, specifically optimized for targeted medical applications, where surface features play a decisive role.en_US
dc.languageengen_US
dc.publisherICMUSTEDen_US
dc.subject33 Ciencias tecnológicasen_US
dc.subject3313 Tecnología e ingeniería mecánicasen_US
dc.subject.otherThin filmsen_US
dc.subject.otherCorrosionen_US
dc.subject.otherGlancing angle depositionen_US
dc.subject.otherTitaniumen_US
dc.subject.otherInclinationen_US
dc.titleInflux of different growth geometries on Titanium thin film for medical applicationsen_US
dc.typeinfo:eu-repo/semantics/conferenceObjecten_US
dc.typeConference proceedingsen_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Actas de congresosen_US
dc.utils.revisionen_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0003-0623-3318-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameBertapelle, Matteo-
crisitem.author.fullNameMirza Rosca, Julia Claudia-
crisitem.author.fullNameViela Vaz,José Filipe-
Appears in Collections:Actas de congresos
Adobe PDF (229,14 kB)
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.