Identificador persistente para citar o vincular este elemento: https://accedacris.ulpgc.es/jspui/handle/10553/149812
Campo DC Valoridioma
dc.contributor.authorRodríguez de Rivera, Pedro Jesús-
dc.contributor.authorRodriguez de Rivera, Miriam-
dc.contributor.authorSocorro, Fabiola-
dc.contributor.authorRodríguez de Rivera, Manuel-
dc.date.accessioned2025-10-13T12:50:48Z-
dc.date.available2025-10-13T12:50:48Z-
dc.date.issued2025-
dc.identifier.issn1388-6150-
dc.identifier.otherWoS-
dc.identifier.urihttps://accedacris.ulpgc.es/jspui/handle/10553/149812-
dc.description.abstractIn this study, we present a new calibration method for a skin calorimeter that allows continuous measurement on the skin without the need for baseline correction. This approach is essential for practical applications that require immediate and uninterrupted monitoring, such as in clinical and physiological studies. The skin calorimeter, designed to measure heat flux, heat capacity, and thermal resistance of a 2 x 2 cm2 skin area, is calibrated using a small aluminum block with a built-in resistor and temperature sensor. Calibration was performed over a range of thermostat temperatures (26-32 degrees C) and Peltier currents (25, 75, and 125 mA), resulting in an accurate model, with a root mean square error (RMSE) of less than 0.15 mW in power measurements. The calorimeter's performance was validated through experiments on human subjects, demonstrating accurate and reliable heat flux measurements without baseline correction. This method simplifies the measurement process and enhances the practical utility of skin calorimetry in various applications.-
dc.languageeng-
dc.relation.ispartofJournal of Thermal Analysis and Calorimetry-
dc.sourceJournal Of Thermal Analysis And Calorimetry [ISSN 1388-6150], (2025)-
dc.subject221308 Técnicas de medida del calor-
dc.subject320106 Dermatología-
dc.subject.otherConduction calorimetry-
dc.subject.otherDirect calorimetry-
dc.subject.otherSkin heat flux-
dc.subject.otherSkin calorimeter-
dc.subject.otherSkin thermal properties-
dc.titleNew calibration method for skin calorimeters without baseline correction for continuous heat flux measurement-
dc.typeinfo:eu-repo/semantics/Article-
dc.typeArticle-
dc.identifier.doi10.1007/s10973-025-14709-4-
dc.identifier.scopus105018231072-
dc.identifier.isi001586266400001-
dc.contributor.orcid0000-0002-6343-6683-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57200590110-
dc.contributor.authorscopusid57202152954-
dc.contributor.authorscopusid6603271349-
dc.contributor.authorscopusid57263601000-
dc.identifier.eissn1588-2926-
dc.investigacionCiencias-
dc.type2Artículo-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.description.numberofpages13-
dc.utils.revision-
dc.contributor.wosstandardWOS:de Rivera, PJR-
dc.contributor.wosstandardWOS:de Rivera, MR-
dc.contributor.wosstandardWOS:Socorro, F-
dc.contributor.wosstandardWOS:de Rivera, MR-
dc.date.coverdate2025-
dc.identifier.ulpgc-
dc.contributor.buulpgcBU-BAS-
dc.description.sjr0,585-
dc.description.jcr3,0-
dc.description.sjrqQ2-
dc.description.jcrqQ2-
dc.description.scieSCIE-
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.orcid0000-0002-6343-6683-
crisitem.author.orcid0000-0002-4890-5947-
crisitem.author.orcid0000-0002-6737-4096-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.fullNameRodríguez De Rivera Socorro, Pedro Jesús-
crisitem.author.fullNameSocorro Lorenzo, Fabiola Lourdes-
crisitem.author.fullNameRodríguez De Rivera Rodríguez, Manuel Jose M.-
Colección:Artículos
Adobe PDF (3 MB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.