Identificador persistente para citar o vincular este elemento:
https://accedacris.ulpgc.es/handle/10553/142197
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Yánez Santana, Manuel Alejandro | en_US |
dc.contributor.author | Cuadrado Hernández, Alberto Javier | en_US |
dc.contributor.author | Fiorucci ,Maria Paula | en_US |
dc.contributor.author | Mentado, Belinda | en_US |
dc.date.accessioned | 2025-07-07T14:00:49Z | - |
dc.date.available | 2025-07-07T14:00:49Z | - |
dc.date.issued | 2025 | en_US |
dc.identifier.issn | 1673-565X | en_US |
dc.identifier.other | Scopus | - |
dc.identifier.uri | https://accedacris.ulpgc.es/handle/10553/142197 | - |
dc.description.abstract | Thoracic reconstructions are essential surgical techniques used to replace severely damaged tissues and restore protection to internal organs. In recent years, advancements in additive manufacturing have enabled the production of thoracic implants with complex geometries, offering more versatile performance. In this study, we investigated a design based on a spring-like geometry manufactured by laser powder bed fusion (LPBF), as proposed in earlier research. The biomechanical behavior of this design was analyzed using various isolated semi-ring-rib models at different levels of the rib cage. This approach enabled a comprehensive examination, leading to the proposal of several implant configurations that were incorporated into a 3D rib cage model with chest wall defects, to simulate different chest wall reconstruction scenarios. The results revealed that the implant design was too rigid for the second rib level, which therefore was excluded from the proposed implant configurations. In chest wall reconstruction simulations, the maximum stresses observed in all prostheses did not exceed 38% of the implant material’s yield stress in the most unfavorable case. Additionally, all the implants showed flexibility compatible with the physiological movements of the human thorax. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Zhejiang University: Science A [ ISSN 1673-565X] | en_US |
dc.source | Journal of Zhejiang University: Science A [ISSN 1673-565X], (Enero 2025) | en_US |
dc.subject | 3313 Tecnología e ingeniería mecánicas | en_US |
dc.subject.other | Chest Wall Reconstruction | en_US |
dc.subject.other | Computational Analysis | en_US |
dc.subject.other | Semi-Ring-Rib Model | en_US |
dc.subject.other | Spring-Like Geometry | en_US |
dc.subject.other | Thoracic Implant | en_US |
dc.title | Computational analysis of Ti-6Al-4V thoracic implants with a spring-like geometry for anterior chest wall reconstruction | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1631/jzus.A2400431 | en_US |
dc.identifier.scopus | 105008922452 | - |
dc.identifier.isi | 001516530200001 | - |
dc.contributor.orcid | 0009-0002-3426-7419 | - |
dc.contributor.orcid | 0000-0002-1736-552X | - |
dc.contributor.orcid | 0000-0002-8599-781X | - |
dc.contributor.orcid | 0000-0002-4532-7520 | - |
dc.contributor.orcid | NO DATA | - |
dc.contributor.authorscopusid | 59960338800 | - |
dc.contributor.authorscopusid | 56423836100 | - |
dc.contributor.authorscopusid | 7005588567 | - |
dc.contributor.authorscopusid | 50561152800 | - |
dc.contributor.authorscopusid | 57217310426 | - |
dc.identifier.eissn | 1862-1775 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 46914483 | - |
dc.contributor.daisngid | 31805198 | - |
dc.contributor.daisngid | 1699742 | - |
dc.contributor.daisngid | 3943463 | - |
dc.contributor.daisngid | 29669753 | - |
dc.description.numberofpages | 15 | en_US |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Bolaños, A | - |
dc.contributor.wosstandard | WOS:Yánez, A | - |
dc.contributor.wosstandard | WOS:Cuadrado, A | - |
dc.contributor.wosstandard | WOS:Fiorucci, MP | - |
dc.contributor.wosstandard | WOS:Mentado, B | - |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
dc.description.sjr | 0,57 | |
dc.description.jcr | 3,4 | |
dc.description.sjrq | Q2 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
dc.description.miaricds | 10,8 | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0002-1736-552X | - |
crisitem.author.orcid | 0000-0002-8599-781X | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Yánez Santana, Manuel Alejandro | - |
crisitem.author.fullName | Cuadrado Hernández, Alberto Javier | - |
crisitem.author.fullName | Fiorucci ,Maria Paula | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.