Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/136845
Campo DC Valoridioma
dc.contributor.authorFukushima, Ryodaien_US
dc.contributor.authorTakamatsu, Toshihiroen_US
dc.contributor.authorSato, Kounosukeen_US
dc.contributor.authorHernández Guedes, Abiánen_US
dc.contributor.authorMarrero Callicó, Gustavo Ivánen_US
dc.contributor.authorOkubo, Kyouheien_US
dc.contributor.authorUmezawa, Masakazuen_US
dc.contributor.authorYokota, Hideoen_US
dc.contributor.authorSoga, Kouheien_US
dc.contributor.authorTakemura, Hiroshien_US
dc.date.accessioned2025-04-01T07:49:49Z-
dc.date.available2025-04-01T07:49:49Z-
dc.date.issued2024en_US
dc.identifier.isbn[9798350312072]en_US
dc.identifier.urihttp://hdl.handle.net/10553/136845-
dc.description.abstractIn this study, a laparoscopic device, which can conduct near-infrared hyperspectral imaging (NIR- HSI) was developed for the first time in the world. The optical system was developed with a spectroscopic element, AOTF, which enables non-invasive acquisition of specimen spectrum in the wavelength range of 490 nm to 1600 nm. Using this system, exposed nerves of living pigs were acquired; a total of four nerves from two pigs were imaged by a neural network using leave-one-out cross-validation procedure. The system provides accuracy of 84.6 %, recall of 65.7 %, and specificity of 85.3 %, respectively. In addition, a detection was performed on a specimen with a 2 mm thick mesentery membrane placed on top of the nerves extracted from a pig. The results were accuracy of 95.2 %, recall of 95.2 %, and specificity of 95.1 %, respectively. Through this study, the developed laparoscopic device is expected to be useful for visualization of tissues in living specimens and in deep tissues of the living body.en_US
dc.languageengen_US
dc.subject3314 Tecnología médicaen_US
dc.titleDetection of Exposed Nerves in Two Individuals In Vivo and Unexposed Nerves Ex Vivo with Near-Infrared Hyperspectral Laparoscopeen_US
dc.typeConference Paperen_US
dc.relation.conference2024 IEEE/SICE International Symposium on System Integration (SII 2024)en_US
dc.identifier.doi10.1109/SII58957.2024.10417671en_US
dc.identifier.scopus2-s2.0-85186263526-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-TELen_US
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos-
crisitem.author.deptIU de Microelectrónica Aplicada-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.orcid0000-0002-2508-2845-
crisitem.author.orcid0000-0002-3784-5504-
crisitem.author.parentorgIU de Microelectrónica Aplicada-
crisitem.author.fullNameHernández Guedes, Abián-
crisitem.author.fullNameMarrero Callicó, Gustavo Iván-
Colección:Actas de congresos
Adobe PDF (758,15 kB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.