Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/136845
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fukushima, Ryodai | en_US |
dc.contributor.author | Takamatsu, Toshihiro | en_US |
dc.contributor.author | Sato, Kounosuke | en_US |
dc.contributor.author | Hernández Guedes, Abián | en_US |
dc.contributor.author | Marrero Callicó, Gustavo Iván | en_US |
dc.contributor.author | Okubo, Kyouhei | en_US |
dc.contributor.author | Umezawa, Masakazu | en_US |
dc.contributor.author | Yokota, Hideo | en_US |
dc.contributor.author | Soga, Kouhei | en_US |
dc.contributor.author | Takemura, Hiroshi | en_US |
dc.date.accessioned | 2025-04-01T07:49:49Z | - |
dc.date.available | 2025-04-01T07:49:49Z | - |
dc.date.issued | 2024 | en_US |
dc.identifier.isbn | [9798350312072] | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/136845 | - |
dc.description.abstract | In this study, a laparoscopic device, which can conduct near-infrared hyperspectral imaging (NIR- HSI) was developed for the first time in the world. The optical system was developed with a spectroscopic element, AOTF, which enables non-invasive acquisition of specimen spectrum in the wavelength range of 490 nm to 1600 nm. Using this system, exposed nerves of living pigs were acquired; a total of four nerves from two pigs were imaged by a neural network using leave-one-out cross-validation procedure. The system provides accuracy of 84.6 %, recall of 65.7 %, and specificity of 85.3 %, respectively. In addition, a detection was performed on a specimen with a 2 mm thick mesentery membrane placed on top of the nerves extracted from a pig. The results were accuracy of 95.2 %, recall of 95.2 %, and specificity of 95.1 %, respectively. Through this study, the developed laparoscopic device is expected to be useful for visualization of tissues in living specimens and in deep tissues of the living body. | en_US |
dc.language | eng | en_US |
dc.subject | 3314 Tecnología médica | en_US |
dc.title | Detection of Exposed Nerves in Two Individuals In Vivo and Unexposed Nerves Ex Vivo with Near-Infrared Hyperspectral Laparoscope | en_US |
dc.type | Conference Paper | en_US |
dc.relation.conference | 2024 IEEE/SICE International Symposium on System Integration (SII 2024) | en_US |
dc.identifier.doi | 10.1109/SII58957.2024.10417671 | en_US |
dc.identifier.scopus | 2-s2.0-85186263526 | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.utils.revision | Sí | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-TEL | en_US |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR IUMA: Diseño de Sistemas Electrónicos Integrados para el procesamiento de datos | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0002-2508-2845 | - |
crisitem.author.orcid | 0000-0002-3784-5504 | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | Hernández Guedes, Abián | - |
crisitem.author.fullName | Marrero Callicó, Gustavo Iván | - |
Appears in Collections: | Actas de congresos |
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.