Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/136686
DC FieldValueLanguage
dc.contributor.authorLeahy, Michael Gen_US
dc.contributor.authorThompson, Kyle M Aen_US
dc.contributor.authorSkattebo, Øyvinden_US
dc.contributor.authorde Paz, Jose Aen_US
dc.contributor.authorMartín Rincón, Marcosen_US
dc.contributor.authorGarcia Gonzalez, Eduardoen_US
dc.contributor.authorGalvan Alvarez,Victoren_US
dc.contributor.authorBoushel ,Roberten_US
dc.contributor.authorHallen,Josteinen_US
dc.contributor.authorBurr, Jamie Fen_US
dc.contributor.authorLópez Calbet, José Antonioen_US
dc.date.accessioned2025-03-18T14:23:22Z-
dc.date.available2025-03-18T14:23:22Z-
dc.date.issued2024en_US
dc.identifier.issn0905-7188en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/136686-
dc.description.abstractCardiac output (Q̇C) and leg blood flow (Q̇LEG) can be measured simultaneously with high accuracy using transpulmonary and femoral vein thermodilution with a single-bolus injection. The invasive measure has offered important insight into leg hemodynamics and blood flow distribution during exercise. Despite being the natural modality of exercise in humans, there has been no direct measure of Q̇LEG while running in humans. We sought to determine the feasibility of the thermodilution technique for measuring Q̇LEG and conductance during high-intensity running, in an exploratory case study. A trained runner (30 years male) completed two maximal incremental tests on a cycle ergometer and motorized treadmill. Q̇LEG and Q̇C were determined using the single-bolus thermodilution technique. Arterial and venous blood were sampled throughout exercise, with continuous monitoring of metabolism, intra-arterial and venous pressure, and temperature. The participant reached a greater peak oxygen uptake (V̇O2peak) during running relative to cycling (74 vs. 68 mL/kg/min) with comparable Q̇LEG (19.0 vs. 19.5 L/min) and Q̇C (27.4 vs. 26.2 L/min). Leg vascular conductance was greater during high-intensity running relative to cycling (82 vs. 70 mL/min/mmHg @ ~80% V̇O2peak). The “beat phenomenon” was apparent in femoral flow while running, producing large gradients in conductance (62–90 mL/min/mmHg @ 70% V̇O2peak). In summary, we present the first direct measure of Q̇LEG and conductance in a running human. Our findings corroborate several assumptions about Q̇LEG during running compared with cycling. Importantly, we demonstrate that using thermodilution in running exercise can be completed effectively and safely.en_US
dc.languageengen_US
dc.relation.ispartofScandinavian Journal Of Medicine And Science In Sportsen_US
dc.sourceScandinavian Journal of Medicine and Science in Sports[ISSN 0905-7188],v. 34 (8), (Agosto 2024)en_US
dc.subject241106 Fisiología del ejercicioen_US
dc.subject.otherCardiac Outputen_US
dc.subject.otherLeg Blood Flowen_US
dc.subject.otherRunningen_US
dc.subject.otherVascular Conductanceen_US
dc.titleAssessing Leg Blood Flow and Cardiac Output During Running Using Thermodilutionen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1111/sms.14705en_US
dc.identifier.scopus85199610891-
dc.identifier.isi001279226200001-
dc.contributor.orcid0000-0002-9209-3982-
dc.contributor.orcidNO DATA-
dc.contributor.orcid0000-0003-0771-9715-
dc.contributor.orcid0000-0002-4389-1777-
dc.contributor.orcid0000-0002-3685-2331-
dc.contributor.orcid0000-0002-0872-9889-
dc.contributor.orcid0000-0002-1272-3471-
dc.contributor.orcidNO DATA-
dc.contributor.orcid0000-0002-6646-0734-
dc.contributor.orcid0000-0002-5449-3352-
dc.contributor.orcid0000-0002-9215-6234-
dc.contributor.authorscopusid57209322577-
dc.contributor.authorscopusid57194147768-
dc.contributor.authorscopusid56711333700-
dc.contributor.authorscopusid58868742600-
dc.contributor.authorscopusid56841673800-
dc.contributor.authorscopusid57804870400-
dc.contributor.authorscopusid57548572600-
dc.contributor.authorscopusid7003471688-
dc.contributor.authorscopusid26656659300-
dc.contributor.authorscopusid23388684200-
dc.contributor.authorscopusid7004323423-
dc.identifier.eissn1600-0838-
dc.identifier.issue8-
dc.relation.volume34en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.description.numberofpages10en_US
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Leahy, MG-
dc.contributor.wosstandardWOS:Thompson, KMA-
dc.contributor.wosstandardWOS:Skattebo, O-
dc.contributor.wosstandardWOS:de Paz, JA-
dc.contributor.wosstandardWOS:Martin-Rincon, M-
dc.contributor.wosstandardWOS:Garcia-Gonzalez, E-
dc.contributor.wosstandardWOS:Galvan-Alvarez, V-
dc.contributor.wosstandardWOS:Boushel, R-
dc.contributor.wosstandardWOS:Hallén, J-
dc.contributor.wosstandardWOS:Burr, JF-
dc.contributor.wosstandardWOS:Calbet, JAL-
dc.date.coverdateAgosto 2024en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-FISen_US
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.orcid0000-0002-3685-2331-
crisitem.author.orcid0000-0002-0872-9889-
crisitem.author.orcid0000-0002-1272-3471-
crisitem.author.orcid0000-0002-9215-6234-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameMartín Rincón, Marcos-
crisitem.author.fullNameGarcia Gonzalez, Eduardo-
crisitem.author.fullNameGalvan Alvarez,Victor-
crisitem.author.fullNameBoushel,Robert-
crisitem.author.fullNameHallen,Jostein-
crisitem.author.fullNameLópez Calbet, José Antonio-
Appears in Collections:Artículos
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.