Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/136686
Title: Assessing Leg Blood Flow and Cardiac Output During Running Using Thermodilution
Authors: Leahy, Michael G
Thompson, Kyle M A
Skattebo, Øyvind
de Paz, Jose A
Martín Rincón, Marcos 
Garcia Gonzalez, Eduardo 
Galvan Alvarez,Victor 
Boushel ,Robert 
Hallen,Jostein 
Burr, Jamie F
López Calbet, José Antonio 
UNESCO Clasification: 241106 Fisiología del ejercicio
Keywords: Cardiac Output
Leg Blood Flow
Running
Vascular Conductance
Issue Date: 2024
Journal: Scandinavian Journal Of Medicine And Science In Sports
Abstract: Cardiac output (Q̇C) and leg blood flow (Q̇LEG) can be measured simultaneously with high accuracy using transpulmonary and femoral vein thermodilution with a single-bolus injection. The invasive measure has offered important insight into leg hemodynamics and blood flow distribution during exercise. Despite being the natural modality of exercise in humans, there has been no direct measure of Q̇LEG while running in humans. We sought to determine the feasibility of the thermodilution technique for measuring Q̇LEG and conductance during high-intensity running, in an exploratory case study. A trained runner (30 years male) completed two maximal incremental tests on a cycle ergometer and motorized treadmill. Q̇LEG and Q̇C were determined using the single-bolus thermodilution technique. Arterial and venous blood were sampled throughout exercise, with continuous monitoring of metabolism, intra-arterial and venous pressure, and temperature. The participant reached a greater peak oxygen uptake (V̇O2peak) during running relative to cycling (74 vs. 68 mL/kg/min) with comparable Q̇LEG (19.0 vs. 19.5 L/min) and Q̇C (27.4 vs. 26.2 L/min). Leg vascular conductance was greater during high-intensity running relative to cycling (82 vs. 70 mL/min/mmHg @ ~80% V̇O2peak). The “beat phenomenon” was apparent in femoral flow while running, producing large gradients in conductance (62–90 mL/min/mmHg @ 70% V̇O2peak). In summary, we present the first direct measure of Q̇LEG and conductance in a running human. Our findings corroborate several assumptions about Q̇LEG during running compared with cycling. Importantly, we demonstrate that using thermodilution in running exercise can be completed effectively and safely.
URI: http://hdl.handle.net/10553/136686
ISSN: 0905-7188
DOI: 10.1111/sms.14705
Source: Scandinavian Journal of Medicine and Science in Sports[ISSN 0905-7188],v. 34 (8), (Agosto 2024)